Addition of fast gas chromatography to selected ion flow tube mass spectrometry for analysis of individual monoterpenes in mixtures
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F19%3A00511863" target="_blank" >RIV/61388955:_____/19:00511863 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11320/19:10397335
Result on the web
<a href="http://hdl.handle.net/11104/0302112" target="_blank" >http://hdl.handle.net/11104/0302112</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5194/amt-12-4965-2019" target="_blank" >10.5194/amt-12-4965-2019</a>
Alternative languages
Result language
angličtina
Original language name
Addition of fast gas chromatography to selected ion flow tube mass spectrometry for analysis of individual monoterpenes in mixtures
Original language description
Soft chemical ionization mass spectrometry (SCI-MS) techniques can be used to accurately quantify volatile organic compounds (VOCs) in air in real time. However, differentiation of isomers still represents a challenge. A suitable pre-separation technique is thus needed, ideally capable of analyses over a few tens of seconds. To this end, a bespoke fast gas chromatography (GC) instrument with an electrically heated 5m long metallic capillary column was coupled to selected ion flow tube mass spectrometry (SIFT-MS) measurements. To assess the performance of this combination, a case study of monoterpene isomer (C10H16) analyses was carried out. The monoterpenes were quantified by SIFT-MS using H3O+ reagent ions (analyte ions C10H17+, m/z 137, and C6H9+, m/z 81) and NO+ reagent ions (analyte ions C10H16+, m/z 136, and C7H9+, m/z 93). The combinations of the fragment ion relative intensities obtained using H3O+ and NO+ were shown to be characteristic of the individual monoterpenes. Two non-polar GC columns (Restek Inc.) were tested: the advantage of MXT-1 was shorter retention, whilst the advantage of MXT-Volatiles was better separation. Thus, it is possible to identify components of a monoterpene mixture in less than 45 s using the MXT-1 column and to separate them in less than 180 s using the MXT-Volatiles column. Quality of the separation and the sensitivity of present technique (limit of detection, LOD, similar to 16 ppbv) was found to be inferior compared to commercially available fast GC solutions coupled with proton transfer reaction mass spectrometry (PTR-MS, LOD similar to 1 ppbv) due to the limited sample flow through the column. However, using combinations of two reagent ions improved identification of monoterpenes not well resolved by the chromatograms. As an illustrative example, the headspace of needle samples of three conifer species was analysed by both reagent ions and with both columns showing that mainly alpha-pinene, beta-pinene and 3-carene were present. The system can thus be used for direct rapid monitoring of monoterpenes above 20 ppbv, such as applications in laboratory studies of monoterpene standards and leaf headspace analysis. Limitation of the sensitivity due to the total sample flow can be improved using a multi-column pre-separation.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10403 - Physical chemistry
Result continuities
Project
<a href="/en/project/GJ17-13157Y" target="_blank" >GJ17-13157Y: New ion chemistry methods for rapid mass spectrometric monitoring of atmospheric biogenic volatile organic compounds responsible for air pollution</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Atmospheric Measurement Techniques
ISSN
1867-1381
e-ISSN
—
Volume of the periodical
12
Issue of the periodical within the volume
9
Country of publishing house
DE - GERMANY
Number of pages
18
Pages from-to
4965-4982
UT code for WoS article
000486661600001
EID of the result in the Scopus database
2-s2.0-85072265436