Screen-printed amalgam electrodes
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F21%3A00544959" target="_blank" >RIV/61388955:_____/21:00544959 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11310/21:10436728
Result on the web
<a href="http://hdl.handle.net/11104/0321745" target="_blank" >http://hdl.handle.net/11104/0321745</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.snb.2021.130583" target="_blank" >10.1016/j.snb.2021.130583</a>
Alternative languages
Result language
angličtina
Original language name
Screen-printed amalgam electrodes
Original language description
Silver amalgam screen-printed electrodes (AgA-SPEs) were designed, prepared and tested for the first time as perspective representatives among SPEs that allow measuring at high negative potentials. For this purpose, the precise electrochemical (coulometric) preparation procedure for mercury deposition at the silver working electrode surface of the commercial silver-SPE was developed and a universal method of preparing amalgam electrodes from different metal-SPEs was described. An optimal electrolyzer construction for the mercury deposition, electrolyte composition, electrolysis potential, and a way to activate the electrode surface for its uniform coverage by mercury were proposed. The effect of the mercury content in amalgam on the potential of hydrogen evolution (PHE) at AgA-SPEs was investigated. The maximum PHE value (−1979 ± 4 mV, RSD = 0.17 %, N = 5) was found on AgA-SPE with 50 % (w/w) of Hg content in 0.1 mol L−1 NaOH, which is more negative than in the case of the original silver-SPE for 387 mV (−1592 ± 12 mV, RSD = 0.69 %, N = 5). Determination of the iodine content in iodinated table salt was used for the AgA-SPEs practical testing. Measurement parameters were optimized for three electrochemical cell arrangements: i) the electrodes area of AgA-SPE was covered by 50 μL of the sample solution and differential pulse voltammetric (DPV) measurements were carried out, ii) 3-electrode batch arrangement with only working electrode from AgA-SPE connected with an analyzer for DPV-measurements, iii) amperometric measurements in a flow system. The results of iodine analysis by all three methods were consistent with the manufacturer declared values.nn
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Result continuities
Project
<a href="/en/project/GA20-01589S" target="_blank" >GA20-01589S: New strategies for improving sensing properties of novel electrode materials via their surface pretreatment or modification</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Sensors and Actuators B - Chemical
ISSN
0925-4005
e-ISSN
0925-4005
Volume of the periodical
347
Issue of the periodical within the volume
NOV 2021
Country of publishing house
CH - SWITZERLAND
Number of pages
8
Pages from-to
130583
UT code for WoS article
000700594000004
EID of the result in the Scopus database
2-s2.0-85112802519