A High-Resolution Mass Spectrometer for the Experimental Study of the Gas Composition in Planetary Environments: First Laboratory Results

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F23%3A00573829" target="_blank" >RIV/61388955:_____/23:00573829 - isvavai.cz</a>

  • Alternative codes found

    RIV/CZ______:_____/23:N0000038

  • Result on the web

    <a href="https://hdl.handle.net/11104/0344182" target="_blank" >https://hdl.handle.net/11104/0344182</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/aerospace10060522" target="_blank" >10.3390/aerospace10060522</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    A High-Resolution Mass Spectrometer for the Experimental Study of the Gas Composition in Planetary Environments: First Laboratory Results

  • Original language description

    A new laboratory OrbitrapTM cell-based mass spectrometer, OLYMPIA (Orbitrap anaLYseur MultiPle IonisAtion), without a C-trap module, has been developed and constructed. The first operation of the OrbitrapTM cell-based device with the continuous ion source and without the C-trap module is reported. OLYMPIA is being developed and used as a workbench platform to test and develop technologies for the next generation of spaceborne mass spectrometers and as a laboratory instrument to perform high-resolution studies of space-relevant chemical processes. This instrument has been used to measure the quantitative composition of CO/N2/C2H4 mixtures of the same nominal mass using an electron ionization ion source. The relative abundance of ions has been measured using a short acquisition time (up to 250 ms) with a precision of better than 10% (for most abundant ions) and a mass resolution of 30,000–50,000 (full width at half maximum) over the mass range of m/z 28–86. The achieved mass accuracy of measurements is better than 20 ppm. This performance level is sufficient to resolve and identify the CO/N2/C2H4 components of the mixtures. The dynamic range and relative ion abundance measurements have been evaluated using a reference normal isotopic distribution of krypton gas. The measurement accuracy is about 10% for the 4 most abundant isotopes, 6 isotopes are detectable.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10403 - Physical chemistry

Result continuities

  • Project

    <a href="/en/project/GC21-11931J" target="_blank" >GC21-11931J: High resolution mass spectrometry laboratory experiments for the analysis of past and future space data.</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Aerospace

  • ISSN

    2226-4310

  • e-ISSN

    2226-4310

  • Volume of the periodical

    10

  • Issue of the periodical within the volume

    6

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    11

  • Pages from-to

    522

  • UT code for WoS article

    001013909100001

  • EID of the result in the Scopus database