Accurate selected ion flow tube mass spectrometry quantification of ethylene oxide contamination in the presence of acetaldehyde

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F23%3A00579116" target="_blank" >RIV/61388955:_____/23:00579116 - isvavai.cz</a>

  • Result on the web

    <a href="https://hdl.handle.net/11104/0347976" target="_blank" >https://hdl.handle.net/11104/0347976</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1039/d3ay01036h" target="_blank" >10.1039/d3ay01036h</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Accurate selected ion flow tube mass spectrometry quantification of ethylene oxide contamination in the presence of acetaldehyde

  • Original language description

    In September 2020, traces of ethylene oxide (a toxic substance used as a pesticide in developing countries but banned for use on food items within the European Union) were found in foodstuffs containing ingredients derived from imported sesame seed products. Vast numbers of foodstuffs were recalled across Europe due to this contamination, leading to expensive market losses and extensive trace exposure of ethylene oxide to consumers. Therefore, a rapid analysis method is needed to ensure food safety by high-throughput screening for ethylene oxide contamination. Selected ion flow tube mass spectrometry (SIFT-MS) is a suitable method for rapid quantification of trace amounts of vapours in the headspace of food samples. It turns out, however, that the presence of acetaldehyde complicates SIFT-MS analyses of its isomer ethylene oxide. It was proposed that a combination of the H3O+ and NO+ reagent ions can be used to analyse ethylene oxide in the presence of acetaldehyde. This method is, however, not robust because of the product ion overlaps and potential interferences from other matrix species. Thus, we studied the kinetics of the reactions of the H3O+, NO+, OH- and O- ions with these two compounds and obtained their rate coefficients and product ion branching ratios. Interpretation of these experimental data revealed that the OH- anions are the most suitable SIFT-MS reagents because the product ions of their reactions with acetaldehyde (CH2CHO- at m/z 43) and ethylene oxide (C2H3O2- at m/z 59) do not overlap.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10403 - Physical chemistry

Result continuities

  • Project

    <a href="/en/project/GA21-25486S" target="_blank" >GA21-25486S: Selected ion flow drift tube mass spectrometry with negative ions and nitrogen carrier gas</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Analytical Methods: advancing methods and applications

  • ISSN

    1759-9660

  • e-ISSN

    1759-9679

  • Volume of the periodical

    15

  • Issue of the periodical within the volume

    46

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    9

  • Pages from-to

    6435-6443

  • UT code for WoS article

    001102848700001

  • EID of the result in the Scopus database

    2-s2.0-85178300230