All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Ion Source with Laser Triangulation for Ambient Mass Spectrometry of Nonplanar Samples

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388963%3A_____%2F17%3A00482600" target="_blank" >RIV/61388963:_____/17:00482600 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11310/17:10365545

  • Result on the web

    <a href="http://dx.doi.org/10.1021/acs.analchem.7b02568" target="_blank" >http://dx.doi.org/10.1021/acs.analchem.7b02568</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1021/acs.analchem.7b02568" target="_blank" >10.1021/acs.analchem.7b02568</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Ion Source with Laser Triangulation for Ambient Mass Spectrometry of Nonplanar Samples

  • Original language description

    The analysis of nonplanar samples in ambient mass spectrometry poses a formidable challenge. Here, an ion source equipped with laser triangulation for analyzing nonplanar surfaces was constructed. It was designed as a two-position device, where the sample height was measured using laser triangulation and the target compounds were then analyzed. Thanks to a stage movable in xyz, the ion source maintained an optimal vertical distance between the sample and the sampling capillary for each measured spot during the surface analysis. The xyz-coordinates for the movement of the sample stage were computed using the laser sensor data in such a way as to avoid direct contact of the sampling capillary and the measured surface. The ion source performance and its ability to analyze various morphologies were tested using desorption electrospray ionization with plastic objects coated by 2,5-dimethoxybenzoic acid. The experiments showed excellent performance for nonplanar samples but also revealed some limitations especially on object edges and steep slopes. The applicability of the ion source operated in desorption electrospray ionization and desorption atmospheric pressure photoionization was examined for food and pharmaceutical samples. Chemicals on the surface of nonplanar samples were probed along a line extending across the surface of the measured objects. The device provided high-quality spectra, regardless of the sample height at the measured spot. The automatic adjustments of the sample stage in xyz proved to be beneficial for analyzing nonplanar samples and for simultaneous measurement of samples with various dimensions and shapes.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Analytical Chemistry

  • ISSN

    0003-2700

  • e-ISSN

  • Volume of the periodical

    89

  • Issue of the periodical within the volume

    21

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    8

  • Pages from-to

    11452-11459

  • UT code for WoS article

    000414887000043

  • EID of the result in the Scopus database