Ion Source with Laser Triangulation for Ambient Mass Spectrometry of Nonplanar Samples
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388963%3A_____%2F17%3A00482600" target="_blank" >RIV/61388963:_____/17:00482600 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11310/17:10365545
Result on the web
<a href="http://dx.doi.org/10.1021/acs.analchem.7b02568" target="_blank" >http://dx.doi.org/10.1021/acs.analchem.7b02568</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acs.analchem.7b02568" target="_blank" >10.1021/acs.analchem.7b02568</a>
Alternative languages
Result language
angličtina
Original language name
Ion Source with Laser Triangulation for Ambient Mass Spectrometry of Nonplanar Samples
Original language description
The analysis of nonplanar samples in ambient mass spectrometry poses a formidable challenge. Here, an ion source equipped with laser triangulation for analyzing nonplanar surfaces was constructed. It was designed as a two-position device, where the sample height was measured using laser triangulation and the target compounds were then analyzed. Thanks to a stage movable in xyz, the ion source maintained an optimal vertical distance between the sample and the sampling capillary for each measured spot during the surface analysis. The xyz-coordinates for the movement of the sample stage were computed using the laser sensor data in such a way as to avoid direct contact of the sampling capillary and the measured surface. The ion source performance and its ability to analyze various morphologies were tested using desorption electrospray ionization with plastic objects coated by 2,5-dimethoxybenzoic acid. The experiments showed excellent performance for nonplanar samples but also revealed some limitations especially on object edges and steep slopes. The applicability of the ion source operated in desorption electrospray ionization and desorption atmospheric pressure photoionization was examined for food and pharmaceutical samples. Chemicals on the surface of nonplanar samples were probed along a line extending across the surface of the measured objects. The device provided high-quality spectra, regardless of the sample height at the measured spot. The automatic adjustments of the sample stage in xyz proved to be beneficial for analyzing nonplanar samples and for simultaneous measurement of samples with various dimensions and shapes.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Analytical Chemistry
ISSN
0003-2700
e-ISSN
—
Volume of the periodical
89
Issue of the periodical within the volume
21
Country of publishing house
US - UNITED STATES
Number of pages
8
Pages from-to
11452-11459
UT code for WoS article
000414887000043
EID of the result in the Scopus database
—