All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Sensitive monitoring of 3-hydroxybutyrate as an indicator of human fasting by capillary electrophoresis in a PAMAMPS coated capillary

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388963%3A_____%2F22%3A00558329" target="_blank" >RIV/61388963:_____/22:00558329 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11120/22:43923601

  • Result on the web

    <a href="https://doi.org/10.1016/j.talanta.2022.123582" target="_blank" >https://doi.org/10.1016/j.talanta.2022.123582</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2022.123582" target="_blank" >10.1016/j.talanta.2022.123582</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Sensitive monitoring of 3-hydroxybutyrate as an indicator of human fasting by capillary electrophoresis in a PAMAMPS coated capillary

  • Original language description

    Sensitive electrophoretic determination of 3-hydroxybutyrate (3HB) as an indicator of human ketogenesis is performed in fused silica capillary covalently coated by an anionic copolymer of poly(acrylamide-co-sodium-2-acrylamido-2-methylpropanesulphonate) (PAMAMPS). Baseline separation of 3HB from other components of human serum is achieved in a 20 μm capillary with an effective length of 17 cm covered by 4% PAMAMPS, which generates a cathodic EOF with a mobility of 8.30 ± 0.00 · 10−9 m2/V.s in 80 mM MES/His as background electrolyte. 3HB migrates in counter-current electrophoretic mode against EOF, that effectively improving electrophoretic resolution. Sample pre-treatment is based on adding of 45 μL acetonitrile to 15 μL serum and, after shaking, a 28 mm long zone of supernatant is injected into the capillary, and sharpened after turning on a separation voltage of 20 kV using the technique of large volume sample stacking, where the EOF forces the residual acetonitrile from the capillary. When combined with universal contactless conductivity detection, the achieved LOD and LOQ are 0.43 μM and 1.44 μM, respectively, that are sufficiently low for monitoring the physiological 3HB level. The performed clinical study subsequently showed that serum 3HB increases from a concentration of 71 μM, corresponding to normal food, to level of 1924 μM after 60 h of fasting and returns to the normal physiological concentration 48 h after commencing consumption of high-saccharide food.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

    1873-3573

  • Volume of the periodical

    247

  • Issue of the periodical within the volume

    September

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    7

  • Pages from-to

    123582

  • UT code for WoS article

    000812357900003

  • EID of the result in the Scopus database

    2-s2.0-85131460667