Multilevel analysis of continuous AE from helicopter gearbox
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F14%3A00438589" target="_blank" >RIV/61388998:_____/14:00438589 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Multilevel analysis of continuous AE from helicopter gearbox
Original language description
Acoustic Emission (AE) analyzers for the purpose of structural health or condition monitoring should provide longtime continuous signal records with relatively high sampling frequency. Recorded huge data must be analyzed to disclose any faults in monitored processes or structures like e.g. leakages in pressure vessels or defects in rotating machines and gearboxes, etc. Fast and reliable AE signal processing and analyzing methods are required. In this paper we present such analysis of continuous AE recorded during tests of renovated helicopter gearboxes. Four-channel continuous AE recording system with 4 MHz sampling rate was used in the tests performed under variable 'flight' simulation regimes. As an alternative to classical spectrogram analysis, we proposed to use histograms of time intervals between crossings of threshold amplitudes (multilevel counting) in the wavelet decomposition details. Results obtained on long-time records are discussed.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
JU - Aeronautics, aerodynamics, aeroplanes
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/FR-TI3%2F755" target="_blank" >FR-TI3/755: *Modernisation of diagnostics system for helicopter engine and drive unit</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů