Dual-capillary apparatus for accurate density measurements of supercooled water

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F18%3A00490827" target="_blank" >RIV/61388998:_____/18:00490827 - isvavai.cz</a>

  • Result on the web

    <a href="https://thermosymposium.nist.gov/pdf/Abstract_4039.pdf" target="_blank" >https://thermosymposium.nist.gov/pdf/Abstract_4039.pdf</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Dual-capillary apparatus for accurate density measurements of supercooled water

  • Original language description

    The properties of supercooled water are interesting from the point of view of fundamental physics underlying the strong anomalies in the supercooled region. At the same time, they are important in many applications (e.g. meteorology, aerospace engineering, cryobiology). Recently, an equation of state has been developed for the region of supercooled water which represents the existing data to within their uncertainties. Further progress in this field depends on the availability of experiments either extending deeper into the supercooled region or providing a significantly better accuracy than the present data. An apparatus designed for high accuracy density measurements of supercooled water up to pressures of 200 MPa has been recently constructed at the Institute of Thermomechanics of the Czech Academy of Sciences. We report about its design and show examples of measured data. The principle of the measurement is based on volume changes of liquid enclosed in custom-treated fused silica capillaries associated with temperature change between a supercooled state and a reference state at the same pressure and a reference temperature (e.g. 298.15 K). Measurement are performed in two capillaries of different length to eliminate the effect of temperature transition. Positions of menisci are measured optically through sapphire windows using a high-resolution camera equipped with a telecentric lens and a glass scale attached to the capillaries. Very high accuracy (uncertainty at the level of 0.01% in density) is enabled by the fact that fused silica has a very small (and well known) coefficient of thermal expansion and the capillary is pressurized from both sides, so that the very small pressure coefficient is only given by the bulk modulus of fused silica.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

  • OECD FORD branch

    20303 - Thermodynamics

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů