Use of energy deposition spectrometer liulin for individual monitoring of aircrew
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F11%3A00360645" target="_blank" >RIV/61389005:_____/11:00360645 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1093/rpd/ncq505" target="_blank" >http://dx.doi.org/10.1093/rpd/ncq505</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncq505" target="_blank" >10.1093/rpd/ncq505</a>
Alternative languages
Result language
angličtina
Original language name
Use of energy deposition spectrometer liulin for individual monitoring of aircrew
Original language description
Silicon energy deposition spectrometer Liulin is used to characterise radiation field on board aircraft, spacecraft, at alpine observatories and at heavy ion accelerators. In this work, calibrations performed in these radiation fields are presented and an improved method developed for calculation of ambient dose equivalent H*(10) on board aircraft is described. Since 2001, a simple method employing the energy deposition spectra had been used to determine H*(10) on board aircraft but, in 2004, it becameclear that the resulting values were strongly biased at locations close to Earth's equator. The improved method took into account the composition of the radiation field via the ratio of absorbed doses D-low and D-neut reflecting the contributions from low-LET particles and neutrons, respectively. It resulted in much better agreement with the EPCARD computer code for all aircraft locations; relative differences were within 11 % for low-LET and 20 % for neutron components of H*(10).
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BG - Nuclear, atomic and molecular physics, accelerators
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2011
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Volume of the periodical
144
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
4
Pages from-to
611-614
UT code for WoS article
000289164200132
EID of the result in the Scopus database
—