All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Impact of cryogenic grinding on iodine homogeneity in NIST SRM 1548a Typical Diet

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F16%3A00466547" target="_blank" >RIV/61389005:_____/16:00466547 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    čeština

  • Original language name

    Vliv kryogenního mletí na homogenitu jódu v NIST SRM1548a Typical Diet

  • Original language description

    The reference material NIST SRM 1548a Typical Diet has a certified iodine mass fraction of 0.7590.103 mg kg-1. The expanded uncertainty is rather large (relative value 13.6 %), thus the material does not provide strict requirements for quality control results. Milling of NIST SRM 1548a at the temperature of liquid nitrogen yielded free-flowing material. Iodine mass fraction in the original and cryo-ground materials was determined by epithermal neutron activation analysis (ENAA) and radiochemical neutron activation analysis (RNAA). The average and standard deviation from both methods was 0.730.03 mg kg-1 (20 values). The determined mass fraction was in a close agreement with the certified value of NIST SRM 1548a, thus iodine total content was not influenced by the milling procedure. In comparison to iodine mass fraction determined in the original NIST SRM 1548a 0.720.07 mg kg-1 (average standard deviation, 14 values), the standard deviation for cryo-ground material was considerably lower. The prepared quality control material sets up more stringent requirements on the validation and quality control procedures of the measurement of iodine mass fraction in such a composite food matrices. We believe that the iodine random inhomogeneity in the original NIST SRM 1548a is due to insufficient mixing of some iodine-rich component in the complex food matrices. Milling at the temperature of liquid nitrogen offers an effective option for production of future reference materials of this kind.

  • Czech name

    Vliv kryogenního mletí na homogenitu jódu v NIST SRM1548a Typical Diet

  • Czech description

    The reference material NIST SRM 1548a Typical Diet has a certified iodine mass fraction of 0.7590.103 mg kg-1. The expanded uncertainty is rather large (relative value 13.6 %), thus the material does not provide strict requirements for quality control results. Milling of NIST SRM 1548a at the temperature of liquid nitrogen yielded free-flowing material. Iodine mass fraction in the original and cryo-ground materials was determined by epithermal neutron activation analysis (ENAA) and radiochemical neutron activation analysis (RNAA). The average and standard deviation from both methods was 0.730.03 mg kg-1 (20 values). The determined mass fraction was in a close agreement with the certified value of NIST SRM 1548a, thus iodine total content was not influenced by the milling procedure. In comparison to iodine mass fraction determined in the original NIST SRM 1548a 0.720.07 mg kg-1 (average standard deviation, 14 values), the standard deviation for cryo-ground material was considerably lower. The prepared quality control material sets up more stringent requirements on the validation and quality control procedures of the measurement of iodine mass fraction in such a composite food matrices. We believe that the iodine random inhomogeneity in the original NIST SRM 1548a is due to insufficient mixing of some iodine-rich component in the complex food matrices. Milling at the temperature of liquid nitrogen offers an effective option for production of future reference materials of this kind.

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Sborník přednášek z 6. ročníku konference Analytické standardy a vybavení

  • ISBN

    978-80-86380-82-7

  • ISSN

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    23-28

  • Publisher name

    2THETA

  • Place of publication

    Český Těšín

  • Event location

    Valtice

  • Event date

    Nov 11, 2016

  • Type of event by nationality

    EUR - Evropská akce

  • UT code for WoS article