Performance tests and comparison of microdosimetric measurements with four tissue-equivalent proportional counters in scanning proton therapy

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F17%3A00473762" target="_blank" >RIV/61389005:_____/17:00473762 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.radmeas.2016.12.005" target="_blank" >http://dx.doi.org/10.1016/j.radmeas.2016.12.005</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.radmeas.2016.12.005" target="_blank" >10.1016/j.radmeas.2016.12.005</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Performance tests and comparison of microdosimetric measurements with four tissue-equivalent proportional counters in scanning proton therapy

  • Original language description

    This paper compares the performance of four different Tissue-Equivalent proportional counters (TEPC) first in standard radiation fields, with gamma and neutron sources, then in the mixed and complex/intense neutron and photon stray radiation field of a scanning proton therapy facility. The paper focuses on the dead time correction and introduces a new spectra processing methodology to enable the comparison of the four TEPCs while accounting for their different gas filling and gain, lineal energy range of the spectrum and the analysis methodology. Measurements with Cs-137 and/or Co-60 gamma sources demonstrate variable low-LET threshold for each TEPC while data acquired with a Cf-252 neutron source show comparable response of the four TEPCs for high-LET particles. Meanwhile, in the scattered field of proton therapy, microdosimetric spectra measured at different positions and orientations around the patient show a majority of high-LET events at the smallest angle with respect to the beam axis while low LET particles were mainly dominant at 90 from the beam axis. The introduced processing methodology led to good overlapping of microdosimetric spectra for the four systems.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20305 - Nuclear related engineering; (nuclear physics to be 1.3);

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Measurements

  • ISSN

    1350-4487

  • e-ISSN

  • Volume of the periodical

    96

  • Issue of the periodical within the volume

    JAN

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    11

  • Pages from-to

    42-52

  • UT code for WoS article

    000392887300005

  • EID of the result in the Scopus database

    2-s2.0-85006758427