All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Dose distribution of secondary radiation in a water phantom for a proton pencil beam-EURADOS WG9 intercomparison exercise

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F18%3A00489292" target="_blank" >RIV/61389005:_____/18:00489292 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1088/1361-6560/aab469" target="_blank" >http://dx.doi.org/10.1088/1361-6560/aab469</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1361-6560/aab469" target="_blank" >10.1088/1361-6560/aab469</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Dose distribution of secondary radiation in a water phantom for a proton pencil beam-EURADOS WG9 intercomparison exercise

  • Original language description

    Systematic 3D mapping of out-of-field doses induced by a therapeutic proton pencil scanning beam in a 300 x 300 x 600 mm(3) water phantom was performed using a set of thermoluminescence detectors (TLDs): MTS-7 ((LiF)-Li-7:Mg, Ti), MTS-6 ((LiF)-Li-6:Mg, Ti), MTS-N ((LiF)-Li-nat:Mg, Ti) and TLD-700 ((LiF)-Li-7: Mg, Ti), radiophotoluminescent (RPL) detectors GD-352M and GD-302M, and polyallyldiglycol carbonate (PADC)-based (C12H18O7) track-etched detectors. Neutron and gamma-ray doses, as well as linear energy transfer distributions, were experimentally determined at 200 points within the phantom. In parallel, the Geant4 Monte Carlo code was applied to calculate neutron and gamma radiation spectra at the position of each detector. For the cubic proton target volume of 100 x 100 x 100 mm(3) (spread out Bragg peak with a modulation of 100 mm) the scattered photon doses along the main axis of the phantom perpendicular to the primary beam were approximately 0.5 mGy Gy(-1) at a distance of 100 mm and 0.02 mGy Gy(-1) at 300 mm from the center of the target. For the neutrons, the corresponding values of dose equivalent were found to be similar to 0.7 and similar to 0.06 mSv Gy(-1), respectively. The measured neutron doses were comparable with the out-offield neutron doses from a similar experiment with 20 MV x-rays, whereas photon doses for the scanning proton beam were up to three orders of magnitude lower.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30224 - Radiology, nuclear medicine and medical imaging

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Physics in Medicine and Biology

  • ISSN

    0031-9155

  • e-ISSN

  • Volume of the periodical

    63

  • Issue of the periodical within the volume

    8

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    13

  • Pages from-to

  • UT code for WoS article

    000430476400007

  • EID of the result in the Scopus database

    2-s2.0-85046457369