All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Calibration of high voltages at the ppm level by the difference of Kr-83m conversion electron lines at the KATRIN experiment

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F18%3A00490014" target="_blank" >RIV/61389005:_____/18:00490014 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1140/epjc/s10052-018-5832-y" target="_blank" >http://dx.doi.org/10.1140/epjc/s10052-018-5832-y</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1140/epjc/s10052-018-5832-y" target="_blank" >10.1140/epjc/s10052-018-5832-y</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Calibration of high voltages at the ppm level by the difference of Kr-83m conversion electron lines at the KATRIN experiment

  • Original language description

    The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at - 18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two Kr-83m conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor M = 1972.449(10) of the high-voltage divider K35 is in agreement with the last PTB calibration 4 years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.

  • Czech name

    —

  • Czech description

    —

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

    —

  • OECD FORD branch

    10303 - Particles and field physics

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    European Physical Journal C

  • ISSN

    1434-6044

  • e-ISSN

    —

  • Volume of the periodical

    78

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    7

  • Pages from-to

    —

  • UT code for WoS article

    000432077800004

  • EID of the result in the Scopus database

    2-s2.0-85046632575