All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Digital pixel test structures implemented in a 65 nm CMOS process

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F23%3A00582691" target="_blank" >RIV/61389005:_____/23:00582691 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1016/j.nima.2023.168589" target="_blank" >https://doi.org/10.1016/j.nima.2023.168589</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.nima.2023.168589" target="_blank" >10.1016/j.nima.2023.168589</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Digital pixel test structures implemented in a 65 nm CMOS process

  • Original language description

    The ALICE ITS3 (Inner Tracking System 3) upgrade project and the CERN EP R&D on monolithic pixel sensors are investigating the feasibility of the Tower Partners Semiconductor Co. 65 nm process for use in the next generation of vertex detectors. The ITS3 aims to employ wafer-scale Monolithic Active Pixel Sensors thinned down to 20–40 µm and bent to form truly cylindrical half barrels. Among the first critical steps towards the realisation of this detector is to validate the sensor technology through extensive characterisation both in the laboratory and with in-beam measurements. The Digital Pixel Test Structure (DPTS) is one of the prototypes produced in the first sensor submission in this technology and has undergone a systematic measurement campaign whose details are presented in this article. The results confirm the goals of detection efficiency and non-ionising and ionising radiation hardness up to the expected levels for ALICE ITS3 and also demonstrate operation at +20 °C and a detection efficiency of 99% for a DPTS irradiated with a dose of 1015 1 MeV neq cm-2. Furthermore, spatial, timing and energy resolutions were measured at various settings and irradiation levels.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

    <a href="/en/project/LM2023040" target="_blank" >LM2023040: Research infrastructure for experiments at CERN</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Nuclear Instruments & Methods in Physics Research Section A

  • ISSN

    0168-9002

  • e-ISSN

    1872-9576

  • Volume of the periodical

    1056

  • Issue of the periodical within the volume

    NOV

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    13

  • Pages from-to

    168589

  • UT code for WoS article

    001155138600001

  • EID of the result in the Scopus database

    2-s2.0-85171618072