The influence of the length of the degradable segment on the functional properties and hydrolytic stability of multi-component polyurethane elastomeric films
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389013%3A_____%2F17%3A00470832" target="_blank" >RIV/61389013:_____/17:00470832 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.polymdegradstab.2017.01.021" target="_blank" >http://dx.doi.org/10.1016/j.polymdegradstab.2017.01.021</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.polymdegradstab.2017.01.021" target="_blank" >10.1016/j.polymdegradstab.2017.01.021</a>
Alternative languages
Result language
angličtina
Original language name
The influence of the length of the degradable segment on the functional properties and hydrolytic stability of multi-component polyurethane elastomeric films
Original language description
The hydrolytic degradation of aliphatic polyurethane (PU) films made from polycarbonate-based macrodiol (MD), diisocyanate-1,6-hexane, butane-1,4-diol (BD) and d,l-lactide-based oligomeric diol (DLL) was studied. The influence of the length of DLL was tested in phosphate-buffered saline (PBS) for periods of up to 12 months. One macrodiol (molecular weight similar to 2000 Da), three DLL oligomers (similar to 400,660 and 850 Da) and three MD-to-BD-to-DLL molar ratios were chosen for the PU synthesis. The isocyanate-to-total hydroxyl-group ratio was kept constant at 1.05. The functional properties of raw polyurethane films and samples immersed for 1,3,6,9 and 12 months in a model physiological environment (37 °C, pH = 7.4) were studied from the segmental to the macroscopic level. Tensile testing and water uptake experiments, as well as differential scanning calorimetry (DSC), scanning electron microscopy (SEM), atomic force microscopy (AFM), Fourier-transform infrared spectroscopy (FTIR) and wide-angle X-ray diffraction (XRD) analyses, were used for the characterization of the raw and PBS-treated films. The study shows that the length of the DLL chain is much more important for functional PU properties than the mass content of DLL in the PU film. The incorporation of the shortest DLL into the PU backbone leads to a degradable PU material with outstanding tensile properties when not subjected to the hydrolytic treatment. However, the incorporation of oligomers with longer DLL chains results in PU materials with substantially deteriorated tensile characteristics due to more pronounced phase separation compared to systems without DLL or with the shortest DLL. The degradability of the PU films can be controlled to a relatively broad extent by altering DLL content and length. The investigation of functional properties of new PU materials during the hydrolytic process under physiology-mimicking conditions is important for potential medical/package coating/film applications.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10404 - Polymer science
Result continuities
Project
<a href="/en/project/GA13-06700S" target="_blank" >GA13-06700S: Multifunctional highly elastic polymeric materials with controlled biodegradability</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Polymer Degradation and Stability
ISSN
0141-3910
e-ISSN
—
Volume of the periodical
137
Issue of the periodical within the volume
March
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
13
Pages from-to
216-228
UT code for WoS article
000396948100020
EID of the result in the Scopus database
2-s2.0-85012108669