Targeted polymer-based probes for fluorescence guided visualization and potential surgery of EGFR-positive head-and-neck tumors
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389013%3A_____%2F20%3A00519002" target="_blank" >RIV/61389013:_____/20:00519002 - isvavai.cz</a>
Alternative codes found
RIV/00064203:_____/20:10410826 RIV/00216208:11110/20:10410826
Result on the web
<a href="https://www.mdpi.com/1999-4923/12/1/31" target="_blank" >https://www.mdpi.com/1999-4923/12/1/31</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/pharmaceutics12010031" target="_blank" >10.3390/pharmaceutics12010031</a>
Alternative languages
Result language
angličtina
Original language name
Targeted polymer-based probes for fluorescence guided visualization and potential surgery of EGFR-positive head-and-neck tumors
Original language description
This report describes the design, synthesis and evaluation of tumor-targeted polymer probes to visualize epidermal growth factor receptor (EGFR)-positive malignant tumors for successful resection via fluorescence guided endoscopic surgery. Fluorescent polymer probes of various molecular weights enabling passive accumulation in tumors via enhanced permeability and retention were prepared and evaluated, showing an optimal molecular weight of 200,000 g/mol for passive tumor targeting. Moreover, poly(N-(2-hydroxypropyl)methacrylamide)-based copolymers labeled with fluorescent dyes were targeted with the EGFR-binding oligopeptide GE-11 (YHWYGYTPQNVI), human EGF or anti-EGFR monoclonal antibody cetuximab were all able to actively target the surface of EGFR-positive tumor cells. Nanoprobes targeted with GE-11 and cetuximab showed the best targeting profile but differed in their tumor accumulation kinetics. Cetuximab increased tumor accumulation after 15 min, whereas GE 11 needed at least 4 h. Interestingly, after 4 h, there were no significant differences in tumor targeting, indicating the potential of oligopeptide targeting for fluorescence-navigated surgery. In conclusion, fluorescent polymer probes targeted by oligopeptide GE-11 or whole antibody are excellent tools for surgical navigation during oncological surgery of head and neck squamous cell carcinoma, due to their relatively simple design, synthesis and cost, as well as optimal pharmacokinetics and accumulation in tumors.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10404 - Polymer science
Result continuities
Project
<a href="/en/project/NV16-28594A" target="_blank" >NV16-28594A: Advanced method for fluorescence-guided endoscopic surgery</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Pharmaceutics
ISSN
1999-4923
e-ISSN
—
Volume of the periodical
12
Issue of the periodical within the volume
1
Country of publishing house
CH - SWITZERLAND
Number of pages
16
Pages from-to
1-16
UT code for WoS article
000514655800047
EID of the result in the Scopus database
2-s2.0-85078558668