Plasma response to n=2 HFS RMP fields on COMPASS.
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F17%3A00484272" target="_blank" >RIV/61389021:_____/17:00484272 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Plasma response to n=2 HFS RMP fields on COMPASS.
Original language description
At present, tokamak COMPASS is the only ITER-like geometry device that operates HFS RMP coils. In this work, fresh and unique experimental results of the HFS RMP field effect on ELMs are presented and compared to those of LFS RMP. It is shown that HFS RMP does not seem to induce density pump-out, unlike LFS RMP, while still causing ELM mitigation and affecting density gradient in pedestal as shown with Li-BES measurements. Measured magnetic plasma response to the RMP is compared to the one simulated by MARS-F and a satisfactory agreement is found.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
—
OECD FORD branch
10305 - Fluids and plasma physics (including surface physics)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů