An improved model for the accurate calculation of parallel heat fluxes at the JET bulk tungsten outer divertor
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F18%3A00495985" target="_blank" >RIV/61389021:_____/18:00495985 - isvavai.cz</a>
Result on the web
<a href="http://iopscience.iop.org/article/10.1088/1741-4326/aad83e/pdf" target="_blank" >http://iopscience.iop.org/article/10.1088/1741-4326/aad83e/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1741-4326/aad83e" target="_blank" >10.1088/1741-4326/aad83e</a>
Alternative languages
Result language
angličtina
Original language name
An improved model for the accurate calculation of parallel heat fluxes at the JET bulk tungsten outer divertor
Original language description
Parallel heat flux calculations at the JET divertor have been based on the assumption that all incoming heat is due to the projection of the heat flux parallel to the magnetic line, q, plus a constant background. This simplification led to inconsistencies during the analysis of a series of dedicated tungsten melting experiments performed in 2013, for which infrared (IR) thermography surface measurements could not be recreated through simulations unless the parallel heat flux was reduced by 80% for L-mode and 60% for H-mode. We give an explanation for these differences using a new IR inverse analysis code, a set of geometrical corrections, and most importantly an additional term for the divertor heat flux accounting for non-parallel effects such as cross-field transport, recycled neutrals or charge exchange. This component has been evaluated comparing four different geometries with impinging angles varying from 2 to 90 degrees. Its magnitude corresponds to 1.2%-1.9% of q(parallel to), but because it is not affected by the magnetic projection, it accounts for up to 20%-30% of the tile surface heat flux. The geometrical corrections imply a further reduction of 24% of the measured heat flux. In addition, the application of the new inverse code increases the accuracy of the tile heat flux calculation, eliminating any previous discrepancy. The parallel heat flux computed with this new model is actually much lower than previously deduced by inverse analysis of IR temperatures-40% for L-mode and 50% for H-mode-while being independent of the geometry on which it is measured. This main result confirms the validity of the optical projection as long as a non-constant and non-parallel component is considered. For a given total heating power, the model predicts over 10% reduction of the maximum tile surface heat flux compared to strict optical modelling, as well as a 30% reduced sensitivity to manufacturing and assembling tolerances. These conclusions, along with the improvement in the predictability of the divertor thermal behaviour, are critical for JET future DT operations, and are also directly applicable to the design of the ITER divertor monoblocks.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10305 - Fluids and plasma physics (including surface physics)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Nuclear Fusion
ISSN
0029-5515
e-ISSN
—
Volume of the periodical
58
Issue of the periodical within the volume
10
Country of publishing house
AT - AUSTRIA
Number of pages
17
Pages from-to
—
UT code for WoS article
000443247800003
EID of the result in the Scopus database
2-s2.0-85053392766