A lanthanum bromide detector of runaway electrons for TCV

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F25%3A00648099" target="_blank" >RIV/61389021:_____/25:00648099 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21340/25:00385104

  • Result on the web

    <a href="https://pubs.aip.org/aip/rsi/article/96/9/093501/3361441/A-lanthanum-bromide-detector-of-runaway-electrons" target="_blank" >https://pubs.aip.org/aip/rsi/article/96/9/093501/3361441/A-lanthanum-bromide-detector-of-runaway-electrons</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1063/5.0277312" target="_blank" >10.1063/5.0277312</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    A lanthanum bromide detector of runaway electrons for TCV

  • Original language description

    The safe control and dissipation of Runaway Electrons (REs) generated in tokamak plasmas is vital for the operation of future fusion reactors. Measuring the evolution of RE energy in tokamaks is important for understanding their generation, transport, and termination. A new gamma ray spectrometer using a 2″ × 2″ cylindrical, cerium doped lanthanum bromide (LaBr3:Ce) scintillator coupled to a fast photomultiplier tube was developed for studying runaway electrons on the Tokamak à Configuration Variable (TCV). This diagnostic is capable of measuring the RE bremsstrahlung energy spectrum between 1 and 20 MeV with a peak height resolution of 1.91% at 1.44 MeV. A calibration of the detector using its self-emission up to 2.66 MeV was performed and modeled using Geant4. This model was then applied to predict the detector response to photons originating from TCV. The diagnostic was employed to measure the high energy Hard X-Ray (HXR) spectrum with energies in the range from 0.5 MeV to ∼ 8 M e V on TCV for the first time. In TCV, the observations made with this system are demonstrated to provide insights into the change in RE energies during current ramps.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Review of Scientific Instruments

  • ISSN

    0034-6748

  • e-ISSN

    1089-7623

  • Volume of the periodical

    96

  • Issue of the periodical within the volume

    9

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    10

  • Pages from-to

    093501

  • UT code for WoS article

    001566040600001

  • EID of the result in the Scopus database

    2-s2.0-105015298327