Label-free impedimetric detection of isopentenyladenine towards noninvasive monitoring of root-microbe interactions
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389030%3A_____%2F26%3A00645864" target="_blank" >RIV/61389030:_____/26:00645864 - isvavai.cz</a>
Alternative codes found
RIV/86652079:_____/26:00645864
Result on the web
<a href="https://doi.org/10.1016/j.jelechem.2025.119682" target="_blank" >https://doi.org/10.1016/j.jelechem.2025.119682</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jelechem.2025.119682" target="_blank" >10.1016/j.jelechem.2025.119682</a>
Alternative languages
Result language
angličtina
Original language name
Label-free impedimetric detection of isopentenyladenine towards noninvasive monitoring of root-microbe interactions
Original language description
Quantifying plant hormones (phytohormones) is essential for understanding plant growth and development. Among the phytohormones, cytokinins are crucial for plant growth, and have also emerged as interkingdom signaling molecules between roots and root-associated microbes. However, existing methods do not allow for non-invasive, in-situ hormone level determination in these interactions. Here we present a label-free electrochemical impedance spectroscopy (EIS) immunosensor to detect the cytokinin molecule, isopentenyladenine (iP) by immobilizing a monoclonal antibody on a self-assembled monolayer (SAM)-modified screen-printed gold electrode (SPAuE). For small molecule measurements using such antibody-based sensors, signal drift in EIS measurements is very common leading to false positive or false negative signals. To address this issue of signal drift, we incubated the antibody-modified electrodes in nitrogen-purged, deaerated phosphate-buffered saline (N-PBS), which resulted in more reproducible and accurate measurements. After incubating the immunosensor with iP in N-PBS, it had a linear response to iP in the concentration range 10-1000 nM with minimal interference towards common small molecules co-existing in plant samples. Finally, the immunosensor was incubated with spiked concentrations of iP in plant root exudate where a linear response to iP was found in the concentration range 100-1000 nM. The developed immunosensor has the potential to quantify other cytokinin molecules with minor modifications.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2026
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Electroanalytical Chemistry
ISSN
1572-6657
e-ISSN
1873-2569
Volume of the periodical
1001
Issue of the periodical within the volume
JAN 15
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
8
Pages from-to
119682
UT code for WoS article
001635591900001
EID of the result in the Scopus database
2-s2.0-105029936707