Reliability of a measurement technique for Achilles tendon length

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17450%2F19%3AA2002011" target="_blank" >RIV/61988987:17450/19:A2002011 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.tandfonline.com/doi/full/10.1080/02640414.2019.1635375" target="_blank" >https://www.tandfonline.com/doi/full/10.1080/02640414.2019.1635375</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1080/02640414.2019.1635375" target="_blank" >10.1080/02640414.2019.1635375</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Reliability of a measurement technique for Achilles tendon length

  • Original language description

    Recently, there has been an increasing amount of literature dealing with new methods of Achilles tendon (AT) length measurement. However, most of these studies measured the AT length between the calcaneus and medial head of the gastrocnemius and the reliability of such a measurement has not been satisfactorily presented. The purpose of this study was to determine the reliability of the measurement of AT length within and between sessions. AT length was measured by using a combination of ultrasound imaging and optoelectronic stereophotogrammetry. Nineteen healthy athletes visited the lab on six different days where the AT length was measured on both lower extremities: 1) from the calcaneus to the mid-point of the medial and lateral heads of the gastrocnemius; and 2) from the calcaneus to the soleus musculotendinous attachment. The reliability results indicated high intraclass correlation coefficients (ICC > 0.8), a low typical error (&lt; 0.6) and a standard error of measurement (SEM &lt; 5.5 mm) for all measured AT lengths on within and between sessions. This non-invasive reliable measurement method may be recommended for sport science research purposes.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30306 - Sport and fitness sciences

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Sport Sciences

  • ISSN

    0264-0414

  • e-ISSN

    1466-447X

  • Volume of the periodical

    37

  • Issue of the periodical within the volume

    20

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    7

  • Pages from-to

    2389-2395

  • UT code for WoS article

    000475198800001

  • EID of the result in the Scopus database

    2-s2.0-85068103344