Experimental Testing of Punching Shear Resistance of Concrete Foundations
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F17%3A86099165" target="_blank" >RIV/61989100:27120/17:86099165 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Experimental Testing of Punching Shear Resistance of Concrete Foundations
Original language description
Foundation structures, their testing and modelling is a wide area to research. A lot of different concrete elements are tested and modeled in the world. Analysis of interaction between the foundation structures and the subsoil has been developed for many years. For the determination of stress in foundation structure is needed to determine the influence of the stiffness respectively pliability of subsoil to structural internal forces, and vice versa, how the stiffness of the foundation structure affects the resulting subsidence. This paper deals with experimental tests of concrete foundation slabs. Tests are carried out at the steel test frame structure by dimension 2 x 2,5 x 5 m which is placed open air at the Faculty of Civil Engineering in Ostrava. Tested slabs are by dimension 2 x 2 m and have different thickness between 100 and 200mm. A lot of physical quantities are tested in those experiments and experiments are then multidisciplinary because geotechnical, acoustic, strain gauges and deformation measurements are conducted. This paper addresses especially with punching shear analysis and maximum punching resistance. Number of experimental tests of concrete foundation slabs were carried out. Slabs classically reinforced, pre-stressed or FRC were tested but slabs were not reinforced with shear reinforcement. During the experiment, the interaction between the concrete foundation and the subsoil was monitored. Most of slabs were disrupted by punching shear. If the slab was disrupted by punching shear, it was monitored and measured dimension and shape of punching failure and results compared between themselves. Last but not last results from the experiment and results according to design methods used in EC2 are compared in this paper. The maximum shear design force according to EC2 was lower than the one from the experiment.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20102 - Construction engineering, Municipal and structural engineering
Result continuities
Project
<a href="/en/project/GA16-08937S" target="_blank" >GA16-08937S: State of stress and strain of fiber reinforced composites in interaction with the soil environment</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings of the 2nd Czech-China Scientific Conference 2016 : June 7, 2016, Ostrava, Czech Republic
ISBN
978-953-51-2857-1
ISSN
—
e-ISSN
neuvedeno
Number of pages
6
Pages from-to
1-6
Publisher name
InTech
Place of publication
Rijeka
Event location
Ostrava
Event date
Jun 7, 2016
Type of event by nationality
CST - Celostátní akce
UT code for WoS article
—