Assessment of non-ventilated air gap in sloping roof with thermal insulation above wooden rafters

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F19%3A10244202" target="_blank" >RIV/61989100:27120/19:10244202 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.5593/sgem2019/6.2/S26.004" target="_blank" >http://dx.doi.org/10.5593/sgem2019/6.2/S26.004</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.5593/sgem2019/6.2/S26.004" target="_blank" >10.5593/sgem2019/6.2/S26.004</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Assessment of non-ventilated air gap in sloping roof with thermal insulation above wooden rafters

  • Original language description

    When designing a passive house, the emphasis is not only on passive measures consisting mainly of thermal protection and stability of the buildings, but also on the price demand of each of the proposed structures. At present, new construction solutions are often encountered in construction practice [1]. These solutions are not yet tested. The paper deals with energy-efficient buildings in terms of reducing building heat loss. One such solution is to use thermal insulation above wooden rafters. Using the thermal insulation above the rafters eliminates thermal bridges [2]. If the thermal insulation is situated above the wooden rafters in combination with the suspended ceiling construction, a non-ventilated air gap is created. In order to avoid disturbances due to water vapor condensation, a moisture stop must be installed in the roof structure. This vapor-proof membrane must be installed as close as possible to the inner surface of the sloping roof. The paper deals with the assessment of the sloping roof structure with thermal insulation above the rafters with non-ventilated air gap, in terms of building physics. (C) SGEM2019.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20100 - Civil engineering

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    International Multidisciplinary Scientific GeoConference Surveying Geology and Mining Ecology Management, SGEM. Volume 19, Issue 6.2

  • ISBN

    978-619-7408-89-8

  • ISSN

    1314-2704

  • e-ISSN

  • Number of pages

    9

  • Pages from-to

    25-33

  • Publisher name

    STEF92 Technology Ltd.

  • Place of publication

    Sofia

  • Event location

    Albena

  • Event date

    Jun 30, 2019

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article