Effects Of Compressed Air Foam Application On Heat Conditions In Fire Within A Closed Space

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27200%2F15%3A86095174" target="_blank" >RIV/61989100:27200/15:86095174 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.degruyter.com/view/j/tvsbses.2015.10.issue-2/tvsbses-2015-0009/tvsbses-2015-0009.xml?format=INT" target="_blank" >http://www.degruyter.com/view/j/tvsbses.2015.10.issue-2/tvsbses-2015-0009/tvsbses-2015-0009.xml?format=INT</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1515/tvsbses-2015-0009" target="_blank" >10.1515/tvsbses-2015-0009</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Effects Of Compressed Air Foam Application On Heat Conditions In Fire Within A Closed Space

  • Original language description

    This article evaluates the knowledge obtained in firefighting tests using compressed air foam system (CAFS) within a confined space. Six experiments were conducted for verification during the cooling of rooms and the self-extinguishing effect. The simulation was for a fully developed fire within a room. The fuel was chosen to simulate ordinary combustible materials utilized in residential areas. Mantel thermocouples were placed in the rooms to record the temperature changes. Compressed air foam was first applied with a standard fire hose nozzle to the ceiling and then to the epicenter of fire. Fire extinguishing was initiated after reaching the desired temperature in the room. The temperature for the start of fire extinguishing matched the third phaseof development of a fire. Fire extinguishing was terminated after no obvious signs of fire were shown in epicenter of fire. The outputs of the experiments were evaluated on the basis of the amount of time passed for the temperature to dro

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    AQ - Safety and health protection, safety in operating machinery

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Sborník vědeckých prací VŠB - TUO, Řada bezpečnostní inženýrství

  • ISSN

    1801-1764

  • e-ISSN

  • Volume of the periodical

    10

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    6

  • Pages from-to

    20-25

  • UT code for WoS article

  • EID of the result in the Scopus database