Determination of a Suitable Heat Treatment Method for the Titanium Alloy Ti-6Al-4V Endoprosthesis Shank

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27230%2F23%3A10253485" target="_blank" >RIV/61989100:27230/23:10253485 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.webofscience.com/wos/woscc/full-record/WOS:001242776200093" target="_blank" >https://www.webofscience.com/wos/woscc/full-record/WOS:001242776200093</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.37904/metal.2023.4741" target="_blank" >10.37904/metal.2023.4741</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Determination of a Suitable Heat Treatment Method for the Titanium Alloy Ti-6Al-4V Endoprosthesis Shank

  • Original language description

    The article concerns the experimental determination of a suitable method of heat treatment of the shank of a hip arthroplasty, that is, an artificial replacement of the femoral head with the neck, to obtain the mechanical properties required by customer. The hip replacement shank is manufactured from Ti-6Al-4V titanium alloy. As the requirements for the mechanical properties of the hip replacement shank were not met after the hardening process, in this case quenching in water and subsequent tempering, repeated annealing was experimented in a Realistic 2 continuous oven. After each alternative annealing of the hip replacement shank, three circular cross-sectional test bars were made, and then the mechanical properties of the material were evaluated by tensile testing. The tests carried out show that after the first annealing, the mechanical properties of the material may not be satisfactory and therefore it is advisable to repeat the annealing. In this case, the requirements for the mechanical properties of the hip arthroplasty were met after the third annealing.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20301 - Mechanical engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    METAL 2023 : 32nd International Conference on Metallurgy and Materials : conference proceedings : May 17–19, 2023, OREA Congress Hotel Brno, Czech Republic, EU

  • ISBN

    978-80-88365-12-9

  • ISSN

    2694-9296

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    609-614

  • Publisher name

    Tanger

  • Place of publication

    Ostrava

  • Event location

    Brno

  • Event date

    May 17, 2023

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    001242776200093