Efficiency determination of inverter-fed induction motor for low power applications
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F12%3A86084823" target="_blank" >RIV/61989100:27240/12:86084823 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Efficiency determination of inverter-fed induction motor for low power applications
Original language description
The paper presents the measurement results of the efficiency of an induction motor, the new high efficiency class IE2 based on the direct efficiency measurement. For comparison purposes, the motor under test was fed by both a programmable three-phase ACpower source and a frequency converter under the same conditions. The influence of the non-sinusoidal feeding and the harmonic power on the motor efficiency decreasing was investigated. T-model of the induction motor was used for computer simulations.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Przeglad elektrotechniczny
ISSN
0033-2097
e-ISSN
—
Volume of the periodical
10A
Issue of the periodical within the volume
88
Country of publishing house
PL - POLAND
Number of pages
3
Pages from-to
305-307
UT code for WoS article
000309540200065