A hybrid device for electrical impedance tomography and bioelectrical impedance spectroscopy measurement

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F14%3A86092118" target="_blank" >RIV/61989100:27240/14:86092118 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1109/CCECE.2014.6900984" target="_blank" >http://dx.doi.org/10.1109/CCECE.2014.6900984</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/CCECE.2014.6900984" target="_blank" >10.1109/CCECE.2014.6900984</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    A hybrid device for electrical impedance tomography and bioelectrical impedance spectroscopy measurement

  • Original language description

    We proposed a hybrid device, which is capable of measuring either bioelectrical impedance spectroscopy (BIS) or electrical impedance tomography (EIT) based on the Magnitude Ratio and Phase Difference Detection method. Frequency range available for measuring is from 1 kHz to 1 MHz. The device is based on The Freescale Tower system module with S08MM Freescale microcontroller. The proposed device is divided into two modules. One of them includes measurement chain, the second one contains four multiplexers,which connect always four electrodes to the circuit from total amount of sixteen electrodes. Both modules are connected via Tower elevator modules. While measuring impedance the systematic error occured, so we used the Quadratic Interpolation Self-calibration algorithm for calculation of the measured impedance. Calibration was applied on the absolute value of impedance. Calibration on the phase shift has not been done yet, since both input signals to GPD are highly disturbed with the no

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JA - Electronics and optoelectronics

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Canadian Conference on Electrical and Computer Engineering 2014

  • ISBN

    978-1-4799-3099-9

  • ISSN

    0840-7789

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

    1-4

  • Publisher name

    IEEE

  • Place of publication

    Vienna

  • Event location

    Toronto

  • Event date

    May 4, 2014

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000361017900074