Modeling of Blood Perfusion in Dependence of Scanning Angle from LDPI Data
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F17%3A10237605" target="_blank" >RIV/61989100:27240/17:10237605 - isvavai.cz</a>
Result on the web
<a href="http://www.scitepress.org/Papers/2017/61428/61428.pdf" target="_blank" >http://www.scitepress.org/Papers/2017/61428/61428.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5220/0006142801100117" target="_blank" >10.5220/0006142801100117</a>
Alternative languages
Result language
angličtina
Original language name
Modeling of Blood Perfusion in Dependence of Scanning Angle from LDPI Data
Original language description
The paper deals with issue of the modelling and analysis of a scanning angle influence on the blood perfusion, and consequent proposal for their elimination. The first essential step of analysis is angle stabilization. In this step, we utilize special artificial arm allowing for a measuring angle adjustment in the scale of two axes. The modelling allows for simulation of perfusion units (PU) in the form of the quadratic model, which is consequently recalculated in the form of the linear expression. The second part of the analysis deals with the PU modelling in the dependence of the distance. In our analysis, we particularly use a segment of middle finger and forearm. In the last part, we propose theoretical conception of the curvature correction influence. This theoretical proposal leads to the relationship between measured and real PU parameter.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Result continuities
Project
<a href="/en/project/TG01010137" target="_blank" >TG01010137: PRE SEED Fund of VSB-Technical univerzity of Ostrava</a><br>
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies. Volume 1: Biodevices
ISBN
978-989-758-216-5
ISSN
—
e-ISSN
neuvedeno
Number of pages
8
Pages from-to
110-117
Publisher name
SciTePress - Science and Technology Publications
Place of publication
[Portugalsko]
Event location
Porto
Event date
Feb 21, 2017
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000413261800013