A phonocardiographic-based fiber-optic sensor and adaptive filtering system for noninvasive continuous fetal heart rate monitoring
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F17%3A10238300" target="_blank" >RIV/61989100:27240/17:10238300 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/17:00100147 RIV/65269705:_____/17:00068256
Result on the web
<a href="http://www.mdpi.com/1424-8220/17/4/890" target="_blank" >http://www.mdpi.com/1424-8220/17/4/890</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s17040890" target="_blank" >10.3390/s17040890</a>
Alternative languages
Result language
angličtina
Original language name
A phonocardiographic-based fiber-optic sensor and adaptive filtering system for noninvasive continuous fetal heart rate monitoring
Original language description
This paper focuses on the design, realization, and verification of a novel phonocardiographic-based fiber-optic sensor and adaptive signal processing system for noninvasive continuous fetal heart rate (fHR) monitoring. Our proposed system utilizes two Mach-Zehnder interferometeric sensors. Based on the analysis of real measurement data, we developed a simplified dynamic model for the generation and distribution of heart sounds throughout the human body. Building on this signal model, we then designed, implemented, and verified our adaptive signal processing system by implementing two stochastic gradient-based algorithms: the Least Mean Square Algorithm (LMS), and the Normalized Least Mean Square (NLMS) Algorithm. With this system we were able to extract the fHR information from high quality fetal phonocardiograms (fPCGs), filtered from abdominal maternal phonocardiograms (mPCGs) by performing fPCG signal peak detection. Common signal processing methods such as linear filtering, signal subtraction, and others could not be used for this purpose as fPCG and mPCG signals share overlapping frequency spectra. The performance of the adaptive system was evaluated by using both qualitative (gynecological studies) and quantitative measures such as: Signal-to-Noise Ratio—SNR, Root Mean Square Error—RMSE, Sensitivity—S+, and Positive Predictive Value—PPV. © 2017 by the authors. Licensee MDPI, Basel, Switzerland.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20201 - Electrical and electronic engineering
Result continuities
Project
<a href="/en/project/EE2.3.20.0217" target="_blank" >EE2.3.20.0217: The Development of Excellence of the Telecommunication Research Team in Relation to International Cooperation</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Sensors (Switzerland)
ISSN
1424-8220
e-ISSN
—
Volume of the periodical
17
Issue of the periodical within the volume
4
Country of publishing house
CH - SWITZERLAND
Number of pages
26
Pages from-to
—
UT code for WoS article
000400822900231
EID of the result in the Scopus database
2-s2.0-85018467704