A robust PPG-based heart rate monitor for fitness and ehealth applications

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F18%3A10241623" target="_blank" >RIV/61989100:27240/18:10241623 - isvavai.cz</a>

  • Result on the web

    <a href="https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8531082" target="_blank" >https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8531082</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/HealthCom.2018.8531082" target="_blank" >10.1109/HealthCom.2018.8531082</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    A robust PPG-based heart rate monitor for fitness and ehealth applications

  • Original language description

    This paper presents the design and implementation of a Heart Rate Monitor (HRM) based on photoplethysmography (PPG). This optical method is noninvasive and provides a convenient means of implementing a low-cost wearable HRM for eHealth applications. Our novel design consists of a light source that emits a modulated or unmodulated light signal through the finger tissue and measures the changes in the reflected light from the arterial blood. These reflections correspond well with the blood volume changes in synchrony with the heartbeat. Here we aim to provide a detailed description of how to design and implement an HRM device based on two approaches: 1) PPG using an unmodulated light source; 2) PPG using a modulated light source. Noise analysis in these devices enabled us to conceptualize and compare their performance and infer which one offers a better choice for optical heart rate monitoring. Based on the measurement results, the latter approach offers superior performance due to better noise cancellation and higher Signal-to-Noise Ratio (SNR) and is therefore robust against movement artefacts, power line noise, flicker noise of electronic components, as well as background environmental light interference. (C) 2018 IEEE.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

    <a href="/en/project/EF16_019%2F0000867" target="_blank" >EF16_019/0000867: Research Centre of Advanced Mechatronic Systems</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    2018 IEEE 20th International Conference on e-Health Networking, Applications and Services, Healthcom 2018

  • ISBN

    978-1-5386-4294-8

  • ISSN

  • e-ISSN

    neuvedeno

  • Number of pages

    5

  • Pages from-to

  • Publisher name

    IEEE

  • Place of publication

    Piscataway

  • Event location

    Ostrava

  • Event date

    Sep 17, 2018

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article