All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Measuring of fault distance using the fault locator function of protection relay

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F19%3A10242442" target="_blank" >RIV/61989100:27240/19:10242442 - isvavai.cz</a>

  • Result on the web

    <a href="https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8778035" target="_blank" >https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8778035</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/EPE.2019.8778035" target="_blank" >10.1109/EPE.2019.8778035</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Measuring of fault distance using the fault locator function of protection relay

  • Original language description

    This article is focused on fault distance measuring with feeder protection relay REF630 from ABB and its function fault locator. This function provides impedance-based fault location. For measuring was used laboratory at Faculty of Electrical Engineering and Computer Science where is laboratory stand with inbuilt REF630 and fault module and where is also available module of transmission network. With those modules there were measured fault distance in case of phase-to-phase fault and phase-to-earth fault for various values of fault resistance. Parameters of typical 11 kV distribution network was set up in protection relay by ABB software PCM600. In case of phase-to-phase fault measured distance corresponded with parameters of model. However, in case of phase-to-earth fault measured fault distance was more than two times lower than our model. Measurement was repeated with parameters of zero sequence reactance equal to positive sequence rectance. Next results corresponded to our model parameters. All results confirmed assumption that higher fault resistance causes lower accuracy of calculated fault distance.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the 2019 20th International Scientific Conference on Electric Power Engineering, EPE 2019

  • ISBN

    978-1-72811-333-3

  • ISSN

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    249-253

  • Publisher name

    IEEE

  • Place of publication

    Piscataway

  • Event location

    Kouty nad Desnou

  • Event date

    May 15, 2019

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000535890900048