Error Ratio Evaluation of Protection Core of Selected Older Distribution Current Transformers

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F19%3A10244276" target="_blank" >RIV/61989100:27240/19:10244276 - isvavai.cz</a>

  • Result on the web

    <a href="https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8777940" target="_blank" >https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8777940</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/EPE.2019.8777940" target="_blank" >10.1109/EPE.2019.8777940</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Error Ratio Evaluation of Protection Core of Selected Older Distribution Current Transformers

  • Original language description

    Current transformer (CT) is one of the vital devices for metering electrical parameters of distribution and transmission networks. Requirements and specification are described in technical standards for 60 years at least, but ageing and performance after some time of on-site operation have not been described in recent works well, especially in conditions similar to network and climate situation in the Czech Republic. Due to the intended aim of using output values for technical state estimation of network components in RCM strategy development, only protection cores measurement for error ratio evaluation was proposed. The results of two selected older oil-insulated current transformers (5P10 class) from distribution network are presented in the paper. The cores are measured according to the protection CT accuracy class, and also, matching measuring CT accuracy class for a general overview of CT accuracy only. The equipment used for measurement is described. The highest current recordings, ratio error evaluation and values are presented and depicted. Results applicability is discussed. (C) 2019 IEEE.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the 2019 20th International Scientific Conference on Electric Power Engineering, EPE 2019

  • ISBN

    978-1-72811-333-3

  • ISSN

  • e-ISSN

    2376-5631

  • Number of pages

    5

  • Pages from-to

    79-83

  • Publisher name

    IEEE

  • Place of publication

    Piscataway

  • Event location

    Kouty nad Desnou

  • Event date

    May 15, 2019

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000535890900015