Vital sign monitoring: a practical solution by a MR-compatible phonocardiography interferometric probe
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F19%3A10244483" target="_blank" >RIV/61989100:27240/19:10244483 - isvavai.cz</a>
Result on the web
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85081009300&origin=resultslist&sort=plf-f&src=s&sid=ad81b54392db3354b3c37088f048fae0&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2857014879400%29&relpos=22&citeCnt=0&searchTerm=" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85081009300&origin=resultslist&sort=plf-f&src=s&sid=ad81b54392db3354b3c37088f048fae0&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2857014879400%29&relpos=22&citeCnt=0&searchTerm=</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Vital sign monitoring: a practical solution by a MR-compatible phonocardiography interferometric probe
Original language description
This paper deals with the description of S-1-S-1 interval detection of the phonocardiographic signal obtained by a fiber-optic Mach-Zehnder interferometer. A non-invasive measuring probe encapsulated in a bicomponent (base and catalyst) entitled Zhermack ZA 50 LT was designed. The probe is immune to the electromagnetic interferences (EMI) and therefore can be operated under strong magnetic fields. The laboratory results (obtained from 8 volunteers) were compared to the reference electrocardiograph (ECG) signal and evaluated by an objective Bland-Altman (B-A) method. Based on the results, it is possible to say that the S-1-S-1 interval detection with the presented fiber-optic interferometric probe is as reliable as the measurement of time between the R-R wave of the ECG signal since the B-A analysis resulted in 95.59 % samples laid in +/- 1.96 SD. The test carried out in a real Magnetic Resonance Imaging (MRI) environment demonstrated that the presence of the probe in the MRI scanner does not affect the quality of this imaging modality. The developed sensor can be suitable for cardiac triggering.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20201 - Electrical and electronic engineering
Result continuities
Project
<a href="/en/project/FV20581" target="_blank" >FV20581: Device for measurement and processing of biosignals with the use of fiber optic sensors</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of optoelectronics and advanced materials
ISSN
1454-4164
e-ISSN
—
Volume of the periodical
21
Issue of the periodical within the volume
11-12
Country of publishing house
RO - ROMANIA
Number of pages
7
Pages from-to
656-662
UT code for WoS article
000512350200002
EID of the result in the Scopus database
2-s2.0-85081009300