All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Influence of the use of gravity sets in a pressure volumetric infusion pump with an impact on the accuracy of infusion solution flows

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F20%3A10246784" target="_blank" >RIV/61989100:27240/20:10246784 - isvavai.cz</a>

  • Result on the web

    <a href="https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/5478" target="_blank" >https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/5478</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.14311/CTJ.2020.1.04" target="_blank" >10.14311/CTJ.2020.1.04</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Influence of the use of gravity sets in a pressure volumetric infusion pump with an impact on the accuracy of infusion solution flows

  • Original language description

    The subject of the work was the experimental verification of the negative influence of gravity sets in a pressure volumetric infusion pump with an impact on the accuracy of infusion solution dosing. The quality criterion for gravity sets was the accuracy of the flow versus the reference set by the volumetric infusion pump. The solution consisted of 14-hour measurements with two types of gravity sets, Intrafix(R) Primeline sets were used as universal sets and Standardline IS 103 gravity sets. The insulin pump flow rate was set at 300 ml/h and 50 ml/h, and the actual flow rate of the infusion solution was recorded every hour using a graduated cylinder. Used gravity sets were also processed by mechanical tests, unused sets were subjected to these tests and the obtained data were compared with each other. Experiments carried out showed that at the set flow rate of 300 ml/h, the flow error with the universal set was-3% and at a set flow rate of 50 ml/h the error was +2.3%. Flow accuracy using gravity sets was worse, a flow error of-7.2% was detected for a flow rate of 50 ml/h and a flow error of-7.7% was measured for 300 ml/h. The volumetric pump used declares a tolerated inaccuracy of +- 3% when used with standard infusion sets. Based on the data, it can be concluded that the replacement of set types has an influence on the dosage of infusion solutions. (C) 2020, Czech Medical Association J.E. Purkyne. All rights reserved.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>ost</sub> - Miscellaneous article in a specialist periodical

  • CEP classification

  • OECD FORD branch

    20600 - Medical engineering

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Lékař a technika

  • ISSN

    0301-5491

  • e-ISSN

  • Volume of the periodical

    50

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    8

  • Pages from-to

    23-31

  • UT code for WoS article

  • EID of the result in the Scopus database

    2-s2.0-85092592524