Influence of the use of gravity sets in a pressure volumetric infusion pump with an impact on the accuracy of infusion solution flows
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F20%3A10246784" target="_blank" >RIV/61989100:27240/20:10246784 - isvavai.cz</a>
Result on the web
<a href="https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/5478" target="_blank" >https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/5478</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/CTJ.2020.1.04" target="_blank" >10.14311/CTJ.2020.1.04</a>
Alternative languages
Result language
angličtina
Original language name
Influence of the use of gravity sets in a pressure volumetric infusion pump with an impact on the accuracy of infusion solution flows
Original language description
The subject of the work was the experimental verification of the negative influence of gravity sets in a pressure volumetric infusion pump with an impact on the accuracy of infusion solution dosing. The quality criterion for gravity sets was the accuracy of the flow versus the reference set by the volumetric infusion pump. The solution consisted of 14-hour measurements with two types of gravity sets, Intrafix(R) Primeline sets were used as universal sets and Standardline IS 103 gravity sets. The insulin pump flow rate was set at 300 ml/h and 50 ml/h, and the actual flow rate of the infusion solution was recorded every hour using a graduated cylinder. Used gravity sets were also processed by mechanical tests, unused sets were subjected to these tests and the obtained data were compared with each other. Experiments carried out showed that at the set flow rate of 300 ml/h, the flow error with the universal set was-3% and at a set flow rate of 50 ml/h the error was +2.3%. Flow accuracy using gravity sets was worse, a flow error of-7.2% was detected for a flow rate of 50 ml/h and a flow error of-7.7% was measured for 300 ml/h. The volumetric pump used declares a tolerated inaccuracy of +- 3% when used with standard infusion sets. Based on the data, it can be concluded that the replacement of set types has an influence on the dosage of infusion solutions. (C) 2020, Czech Medical Association J.E. Purkyne. All rights reserved.
Czech name
—
Czech description
—
Classification
Type
J<sub>ost</sub> - Miscellaneous article in a specialist periodical
CEP classification
—
OECD FORD branch
20600 - Medical engineering
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Lékař a technika
ISSN
0301-5491
e-ISSN
—
Volume of the periodical
50
Issue of the periodical within the volume
1
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
8
Pages from-to
23-31
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85092592524