Heat Transfer Optimization of NEXA Ballard Low-Temperature PEMFC
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F21%3A10247371" target="_blank" >RIV/61989100:27240/21:10247371 - isvavai.cz</a>
Alternative codes found
RIV/61989100:27730/21:10247371
Result on the web
<a href="https://www.mdpi.com/1996-1073/14/8/2182/pdf" target="_blank" >https://www.mdpi.com/1996-1073/14/8/2182/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/en14082182" target="_blank" >10.3390/en14082182</a>
Alternative languages
Result language
angličtina
Original language name
Heat Transfer Optimization of NEXA Ballard Low-Temperature PEMFC
Original language description
Hydrogen is one of the modern energy carriers, but its storage and practical use of the newest hydrogen technologies in real operation conditions still is a task of future investigations. This work describes the experimental hydrogen hybrid energy system (HHS). HHS is part of a laboratory off-grid system that stores electricity gained from photovoltaic panels (PVs). This system includes hydrogen production and storage units and NEXA Ballard low-temperature proton-exchange membrane fuel cell (PEMFC). Fuel cell (FC) loses a significant part of heat during converting chemical energy into electricity. The main purpose of the study was to explore the heat distribution phenomena across the FC NEXA Ballard stack during load with the next heat transfer optimization. The operation of the FC with insufficient cooling can lead to its overheating or even cell destruction. The cause of this undesirable state is studied with the help of infrared thermography and computational fluid dynamics (CFD) modeling with heat transfer simulation across the stack. The distribution of heat in the stack under various loads was studied, and local points of overheating were determined. Based on the obtained data of the cooling air streamlines and velocity profiles, few ways of the heat distribution optimization along the stack were proposed. This optimization was achieved by changing the original shape of the FC cooling duct. The stable condition of the FC stack at constant load was determined.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20201 - Electrical and electronic engineering
Result continuities
Project
<a href="/en/project/TK03020027" target="_blank" >TK03020027: CEET - Center of Energy and Environmental Technologies</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Energies
ISSN
1996-1073
e-ISSN
—
Volume of the periodical
14
Issue of the periodical within the volume
8
Country of publishing house
CH - SWITZERLAND
Number of pages
17
Pages from-to
1-17
UT code for WoS article
000644169800001
EID of the result in the Scopus database
2-s2.0-85106299907