Combining multi-level feature extraction algorithm with residual graph convolutional neural network for partial discharge detection
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F25%3A10256665" target="_blank" >RIV/61989100:27240/25:10256665 - isvavai.cz</a>
Alternative codes found
RIV/61989100:27730/25:10256665
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S0263224124020360?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0263224124020360?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.measurement.2024.116151" target="_blank" >10.1016/j.measurement.2024.116151</a>
Alternative languages
Result language
angličtina
Original language name
Combining multi-level feature extraction algorithm with residual graph convolutional neural network for partial discharge detection
Original language description
Partial discharge (PD) identification is critical for the insulation diagnosis of cable conductors; however, there is still scope for enhancement in the existing adaptive extraction capabilities and feature utilization for PD signals. In this context, this paper introduces a method that integrates a one-dimensional convolutional neural network (1D-CNN) with a residual graph convolutional neural network (ResGCN) to recognize PD signals. Noise analysis is performed using various combinations of mother wavelets, and Bayesian optimization is employed to mitigate background noise. Key features of PD signals are progressively abstracted through a 1D-CNN-based multilevel automatic feature learning method, while signal timing attributes are maintained to minimize manual intervention. The graph data is constructed using the signal feature matrix and the signal timing feature similarity matrix. This is followed by the development of a ResGCN utilizing a graph attention mechanism to integrate node feature information and the topology of the PD graph data. This approach aims to fully exploit the correlation between local regions of the feature space and the temporal numerical properties of the signals. Additionally, it jointly optimizes feature extraction and model classification to facilitate adaptive diagnosis. The method is validated with extensive real experimental data obtained from medium voltage overhead power lines. It demonstrates exceptional performance and practicality, achieving an accuracy rate of 97.3% and a recognition rate of 96.1% for PD samples, thus offering reliable theoretical support for effective PD detection. © 2024 Elsevier Ltd
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20201 - Electrical and electronic engineering
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Measurement
ISSN
0263-2241
e-ISSN
1873-412X
Volume of the periodical
242
Issue of the periodical within the volume
January
Country of publishing house
US - UNITED STATES
Number of pages
15
Pages from-to
nestránkováno
UT code for WoS article
001356071600001
EID of the result in the Scopus database
2-s2.0-85208460709