Measuring the thermal characteristics of concretes exposed to extreme conditions
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27350%2F17%3A10237166" target="_blank" >RIV/61989100:27350/17:10237166 - isvavai.cz</a>
Alternative codes found
RIV/61989100:27360/17:10237166 RIV/61989100:27740/17:10237166
Result on the web
<a href="https://www.scientific.net/DDF.370.68" target="_blank" >https://www.scientific.net/DDF.370.68</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/DDF.370.68" target="_blank" >10.4028/www.scientific.net/DDF.370.68</a>
Alternative languages
Result language
angličtina
Original language name
Measuring the thermal characteristics of concretes exposed to extreme conditions
Original language description
This article presents the results of an experimental research dealing with the measurement of the thermal characteristics of concretes based on natural and artificial aggregates (steel slag). The samples of concrete composites were prepared on the basis of natural aggregate fractions 0/4, 4/8 and 8/16 mm and on the basis of steel slag fr. 4/8 mm. The volume ratio of the individual aggregate fractions in all experimental mixtures used for the production of concrete composites was 40:30:30 (fr. 0/4: 4/8: 8/16). The prepared samples of concrete composites based on natural aggregate and natural aggregate combined with steel slag were subjected to the tests of strength characteristics, water-tightness, thermal characteristics using a commercial device ISOMET 2104 (measurement of the coefficient of thermal conductivity λ, specific heat capacity c, and the coefficient of thermal diffusivity a), and heating in a prototype calorimetric computercontrolled chamber. The main attention was focused on the testing of the value changes of the coefficients of thermal conductivity λ depending on the changes of temperatures within the range of -5 °C to + 40 °C. The measurements of these thermal characteristics have very high informative value, especially because these material parameters are not tabulated for the newly designed building materials, and that is why they are not examined at extreme temperatures. This is a reason why they cannot be used as important data during the thermal calculations of a non-insulated concrete structure (e.g. using polystyrene and / or glass wool).
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20501 - Materials engineering
Result continuities
Project
<a href="/en/project/LO1406" target="_blank" >LO1406: Institute of clean technologies for mining and utilization of raw materials for energy use -Sustainability program</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Defect and Diffusion Forum. Volume 379
ISSN
1012-0386
e-ISSN
—
Volume of the periodical
370
Issue of the periodical within the volume
370
Country of publishing house
US - UNITED STATES
Number of pages
10
Pages from-to
68-77
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85011016461