Grain Size and Electrochemical Surface Modification Effects on Corrosion, Biological, and Technological Properties of CP Titanium Implants
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27350%2F25%3A10259679" target="_blank" >RIV/61989100:27350/25:10259679 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11140/25:10507395 RIV/61989100:27360/25:10259679 RIV/61989100:27730/25:10259679
Result on the web
<a href="https://www.mdpi.com/2079-4983/16/12/439" target="_blank" >https://www.mdpi.com/2079-4983/16/12/439</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/jfb16120439" target="_blank" >10.3390/jfb16120439</a>
Alternative languages
Result language
angličtina
Original language name
Grain Size and Electrochemical Surface Modification Effects on Corrosion, Biological, and Technological Properties of CP Titanium Implants
Original language description
Commercially pure (CP) titanium is widely used for long-term biomedical implants due to its high biocompatibility and corrosion resistance. However, its relatively low strength limits its use in highly loaded applications. Ultrafine-grained (UFG) titanium obtained through severe plastic deformation offers enhanced mechanical performance while maintaining the stability of CP titanium. This study investigates how electrochemical surface modification by anodization affects the corrosion, biological performance, and technological behavior of UFG titanium. TiO2 layers with nanotubular and nanoporous morphologies were produced at anodization voltages between 20 and 60 V. Corrosion tests in physiological solution confirmed stable passive behavior with corrosion rates below 4 mu m year-1, and surface wettability increased markedly with anodization. Osteoblast-like MG-63 cells exhibited good viability on all anodized surfaces, with improved adhesion and proliferation on samples anodized at 60 V. The porous TiO2 layers were successfully intercalated with dimethyl sulfoxide and ibuprofen, demonstrating potential for local drug delivery. Implantation simulations on real Nanoimplant (R) prototypes confirmed sufficient mechanical stability of the anodized layer. Overall, the optimized anodization of UFG titanium enhances its biological response while maintaining corrosion resistance, supporting its clinical use in long-term dental and orthopedic implants with integrated drug-release functionality.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20501 - Materials engineering
Result continuities
Project
<a href="/en/project/EH22_008%2F0004631" target="_blank" >EH22_008/0004631: Materials and technologies for sustainable development</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Functional Biomaterials
ISSN
2079-4983
e-ISSN
2079-4983
Volume of the periodical
16
Issue of the periodical within the volume
12
Country of publishing house
CH - SWITZERLAND
Number of pages
26
Pages from-to
nestránkováno
UT code for WoS article
001646818800001
EID of the result in the Scopus database
—