Heat output of the recuperator for preheating natural gas from a mobile container device

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F16%3A86099323" target="_blank" >RIV/61989100:27360/16:86099323 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1063/1.4963038" target="_blank" >http://dx.doi.org/10.1063/1.4963038</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1063/1.4963038" target="_blank" >10.1063/1.4963038</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Heat output of the recuperator for preheating natural gas from a mobile container device

  • Original language description

    The paper describes the methodology for determination of the heat exchanger output for mobile container device designed to supply stationary stations with natural gas. Expansion of the gas in the device is considered in two stages. In the first stage from over-pressure of 22 MPa down to over-pressure of 0.4 MPa and then in the second stage to over-pressure of 2.2 kPa or 170 kPa. The overall temperature drop during gas throttling, which depends not only on the initial and final pressure but also on the temperature, was calculated by numerical integration of the Joule-Thomson differential coefficient. For the throttling temperature between 0 and 55 oC, the total temperature drop in the first stage varies between 53.8 and 67.4 K, and in the second stage then up to 2 K. The heat exchanger output was determined by an iterative process. Smooth supply of 600 m3 of natural gas per hour requires a heat exchanger with an output of approx. 26 kW. Gas combustion micro-turbine consumption is of the order of m3 of natural gas per hour.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JG - Metallurgy, metal materials

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/TA04020106" target="_blank" >TA04020106: Design and development of mobile devices container to supply filling stations compressed natural gas</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    AIP Conference Proceedings

  • ISBN

    978-0-7354-1426-6

  • ISSN

    0094-243X

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    1-6

  • Publisher name

    American Institute of Physics Inc.

  • Place of publication

    New York

  • Event location

    Šamorín - Čilistov, Slovak

  • Event date

    Jun 20, 2016

  • Type of event by nationality

    EUR - Evropská akce

  • UT code for WoS article