A Test Stand Study on the Volatile Emissions of a Passenger Car Brake Assembly

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F19%3A10242039" target="_blank" >RIV/61989100:27360/19:10242039 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.mdpi.com/2073-4433/10/5/263" target="_blank" >https://www.mdpi.com/2073-4433/10/5/263</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/atmos10050263" target="_blank" >10.3390/atmos10050263</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    A Test Stand Study on the Volatile Emissions of a Passenger Car Brake Assembly

  • Original language description

    Brake-related airborne particulate matter contributes to urban emissions in the transport sector. Recent research demonstrated a clear dependence of the number of ultra-fine particles on the disc brake temperature. Above the so-called transition temperature, the number of ultra-fine particles increases dramatically (several magnitudes). As for exhaust emissions, part of the emissions released during braking can be in the volatile fraction. For this reason, a disc brake test stand specifically designed for aerosol research was equipped with three different aerosol sampling instruments: (i) a standard cascade impactor, (ii) a cascade impactor operating at high temperature with a heated sampling line, and (iii) a standard cascade impactor with a thermodenuder. Tests with a brake assembly representative of European passenger vehicles were executed, and the concentration of released airborne particles was determined. The results showed a decrease by several magnitudes in the concentration (in the size range of below 200 nm) using the cascade impactor operating at 180 oC with the sampling line heated to 200 oC. A further decrease in the concentration of airborne particles with size fractions below 200 nm was measured using a standard cascade impactor with a thermodenuder heated to 300 oC.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20700 - Environmental engineering

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Atmosphere

  • ISSN

    2073-4433

  • e-ISSN

  • Volume of the periodical

    10

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    14

  • Pages from-to

    263-277

  • UT code for WoS article

    000472677600037

  • EID of the result in the Scopus database

    2-s2.0-85073029878