Functional Properties of Polyurethane Ureteral Stents with PLGA and Papaverine Hydrochloride Coating
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27640%2F21%3A10247982" target="_blank" >RIV/61989100:27640/21:10247982 - isvavai.cz</a>
Result on the web
<a href="https://www.mdpi.com/1422-0067/22/14/7705" target="_blank" >https://www.mdpi.com/1422-0067/22/14/7705</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/ijms22147705" target="_blank" >10.3390/ijms22147705</a>
Alternative languages
Result language
angličtina
Original language name
Functional Properties of Polyurethane Ureteral Stents with PLGA and Papaverine Hydrochloride Coating
Original language description
Despite the obvious benefits of using ureteral stents to drain the ureters, there is also a risk of complications from 80-90%. The presence of a foreign body in the human body causes disturbances in its proper functioning. It can lead to biofilm formation on the stent surface, which may favor the development of urinary tract infections or the formation of encrustation, as well as stent fragmentation, complicating its subsequent removal. In this work, the effect of the polymeric coating containing the active substance-papaverine hydrochloride on the functional properties of ureteral stents significant for clinical practice were assessed. Methods: The most commonly clinically used polyurethane ureteral Double-J stent was selected for the study. Using the dip-coating method, the surface of the stent was coated with a poly(D,L-lactide-glycolide) (PLGA) coating containing the papaverine hydrochloride (PAP). In particular, strength properties, retention strength of the stent ends, dynamic frictional force, and the fluoroscopic visibility of the stent during X-ray imaging were determined. Results: The analysis of the test results indicates the usefulness of a biodegradable polymer coating containing the active substance for the modification of the surface of polyurethane ureteral stents. The stents coated with PLGA+PAP coating compared to polyurethane stents are characterized by more favorable strength properties, the smaller value of the dynamic frictional force, without reducing the fluoroscopic visibility.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10608 - Biochemistry and molecular biology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Journal of Molecular Sciences
ISSN
1422-0067
e-ISSN
—
Volume of the periodical
22
Issue of the periodical within the volume
14
Country of publishing house
CH - SWITZERLAND
Number of pages
12
Pages from-to
—
UT code for WoS article
000676643100001
EID of the result in the Scopus database
2-s2.0-85110583935