Ambient Air Quality Measurement with Low-Cost Optical and Electrochemical Sensors: An Evaluation of Continuous Year-Long Operation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27710%2F21%3A10248052" target="_blank" >RIV/61989100:27710/21:10248052 - isvavai.cz</a>
Alternative codes found
RIV/61989100:27730/21:10248052
Result on the web
<a href="https://www.mdpi.com/2076-3298/8/11/114" target="_blank" >https://www.mdpi.com/2076-3298/8/11/114</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/environments8110114" target="_blank" >10.3390/environments8110114</a>
Alternative languages
Result language
angličtina
Original language name
Ambient Air Quality Measurement with Low-Cost Optical and Electrochemical Sensors: An Evaluation of Continuous Year-Long Operation
Original language description
Sensor technology is attractive to the public due to its availability and ease of use. However, its usage raises numerous questions. The general trustworthiness of sensor data is widely discussed, especially with regard to accuracy, precision, and long-term signal stability. The VSB-Technical University of Ostrava has operated an air quality sensor network for more than two years, and its large sets of valid results can help in understanding the limitations of sensory measurement. Monitoring is focused on the concentrations of dust particles, NO2, and ozone to verify the impact of newly planted greenery on the reduction in air pollution. The sensor network currently covers an open field on the outskirts of Ostrava, between Liberty Ironworks and the nearby ISKO1650 monitoring station, where some of the worst air pollution levels in the Czech Republic are regularly measured. In the future, trees should be allowed to grow over the sensors, enabling assessment of the green barrier effect on air pollution. As expected, the service life of the sensors varies from 1 to 3 years; therefore, checks are necessary both prior to the measurement and regularly during operation, verifying output stability and overall performance. Results of the PMx sensory measurements correlated well with the reference method. Concentration values measured by NO2 sensors correlated poorly with the reference method, although timeline plots of concentration changes were in accordance. We suggest that a comparison of timelines should be used for air quality evaluations, rather than particular values. The results showed that the sensor measurements are not yet suitable to replace the reference methods, and dense sensor networks proved useful and robust tools for indicative air quality measurements (AQM).
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10511 - Environmental sciences (social aspects to be 5.7)
Result continuities
Project
<a href="/en/project/EF18_069%2F0010049" target="_blank" >EF18_069/0010049: Research on the identification of combustion of unsuitable fuels and systems of self-diagnostics of boilers combusting solid fuels for domestic heating</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Environments
ISSN
2076-3298
e-ISSN
—
Volume of the periodical
8
Issue of the periodical within the volume
11
Country of publishing house
CH - SWITZERLAND
Number of pages
13
Pages from-to
114
UT code for WoS article
000724003500001
EID of the result in the Scopus database
2-s2.0-85118104607