A simulation of energy storage system for improving the power system stability with grid-connected pv using MCA analysis and labview tool

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27730%2F15%3A86096177" target="_blank" >RIV/61989100:27730/15:86096177 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.15598/aeee.v13i2.1347" target="_blank" >http://dx.doi.org/10.15598/aeee.v13i2.1347</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.15598/aeee.v13i2.1347" target="_blank" >10.15598/aeee.v13i2.1347</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    A simulation of energy storage system for improving the power system stability with grid-connected pv using MCA analysis and labview tool

  • Original language description

    The large-scale penetration of distributed, Renewable power plants require transfers of large amounts of energy. This, in turn, puts a high strain on the energy delivery infrastructure. In particular, photovoltaic power plants supply energy with high in-termittency, possibly affecting the stability of the grid by changing the voltage at the plant connection point. In this contribution, we summarize the main negative effects of selected and real-operated grid connected photovoltaic plant. Thereafter a review of suitable Energy storage systems to mitigate the negative effects has been carried out, compared and evaluated using Multi-criterion analysis. Based on this analysis, data collected at the plant and the grid, are used to design the energy storagesystems to support connection of the plant to the grid. The cooperation of these systems is then analysed and evaluated using simulation tools created in LabVIEW for this purpose. The simulation results demonstrate the capability ofenergy

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JE - Non-nuclear power engineering, energy consumption and utilization

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Advances in Electrical and Electronic Engineering

  • ISSN

    1336-1376

  • e-ISSN

  • Volume of the periodical

    13

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    10

  • Pages from-to

    127-136

  • UT code for WoS article

  • EID of the result in the Scopus database

    2-s2.0-84936126333