Oxidized phosphatidylcholines suggest oxidative stress in patients with medium-chain acyl-CoA dehydrogenase deficiency
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F15%3A33153666" target="_blank" >RIV/61989592:15110/15:33153666 - isvavai.cz</a>
Alternative codes found
RIV/00098892:_____/15:#0000910
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S003991401500123X" target="_blank" >http://www.sciencedirect.com/science/article/pii/S003991401500123X</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2015.02.041" target="_blank" >10.1016/j.talanta.2015.02.041</a>
Alternative languages
Result language
angličtina
Original language name
Oxidized phosphatidylcholines suggest oxidative stress in patients with medium-chain acyl-CoA dehydrogenase deficiency
Original language description
Inborn errors of metabolism encompass a large group of diseases caused by enzyme deficiencies and are therefore amenable to metabolomics investigations. Medium chain acyl-CoA dehydrogenase deficiency (MCADD) is a defect in ?-oxidation of fatty acids, andis one of the most well understood disorders. We report here the use of liquid chromatography-mass spectrometry (LC-MS) based untargeted metabolomics and targeted flow injection analysis-tandem mass spectrometry (FIA-TMS) that lead to discovery of novelcompounds of oxidative stress. Dry blood spots of controls (n=25) and patient samples (n=25) were extracted by methanol/water (1/1, v/v) and these supernatants were analyzed by LC-MS method with detection by an Orbitrap Elite MS. Data were processed byXCMS and CAMERA followed by dimension reduction methods. Patients were clearly distinguished from controls in PCA. S-plot derived from OPLS-DA indicated that medium-chain acylcarnitines (octanoyl, decenoyl and decanoyl carnitines) as well
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Talanta
ISSN
0039-9140
e-ISSN
—
Volume of the periodical
139
Issue of the periodical within the volume
JUL
Country of publishing house
GB - UNITED KINGDOM
Number of pages
5
Pages from-to
62-66
UT code for WoS article
000353857500010
EID of the result in the Scopus database
—