In situ observation of lubricant film formation in THR considering real conformity: The effect of diameter, clearance and material

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F17%3A73578888" target="_blank" >RIV/61989592:15110/17:73578888 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216305:26210/17:PU121686

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.jmbbm.2016.12.018" target="_blank" >http://dx.doi.org/10.1016/j.jmbbm.2016.12.018</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.jmbbm.2016.12.018" target="_blank" >10.1016/j.jmbbm.2016.12.018</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    In situ observation of lubricant film formation in THR considering real conformity: The effect of diameter, clearance and material

  • Original language description

    The aim of the present study is to provide an analysis of protein film formation in hip joint replacements considering real conformity based on in situ observation of the contact zone. The main attention is focused on the effect of implant nominal diameter, diametric clearance and material. For this purpose, a pendulum hip joint simulator equipped with electromagnetic motors enabling to apply continuous swinging flexion–extension motion was employed. The experimental configuration consists of femoral component (CoCrMo, BIOLOX®forte, BIOLOX®delta) and acetabular cup from optical glass fabricated according to the dimensions of real cups. Two nominal diameters were studied, 28 and 36 mm, respectively, while different diametric clearances were considered. Initially, a static test focused on the protein adsorption onto rubbing surfaces was performed with 36 mm implants. It was found that the development of adsorbed layer is much more stable in the case of metal head, indicating that the adsorption forces are stronger compared to ceramic. A consequential swinging test revealed that the fundamental parameter influencing the protein film formation is diametric clearance. Independently of implant diameter, film was much thicker when a smaller clearance was considered. An increase of implant size from 28 mm to 36 mm did not cause a substantial difference in film formation; however, the total film thickness was higher for smaller implant. In terms of material, metal heads formed a thicker film, while this fact can be, among others, also attributed to clearance, which is more than two times higher in the case of ceramic implant.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20301 - Mechanical engineering

Result continuities

  • Project

    <a href="/en/project/LO1202" target="_blank" >LO1202: NETME CENTRE PLUS</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of the Mechanical Behavior of Biomedical Materials

  • ISSN

    1751-6161

  • e-ISSN

  • Volume of the periodical

    69

  • Issue of the periodical within the volume

    May 2017

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    9

  • Pages from-to

    66-74

  • UT code for WoS article

    000400199600007