Influence of slice thickness on result of CT histogram analysis in indeterminate adrenal masses.
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F19%3A73593563" target="_blank" >RIV/61989592:15110/19:73593563 - isvavai.cz</a>
Result on the web
<a href="https://link.springer.com/content/pdf/10.1007/s00261-018-1835-2.pdf" target="_blank" >https://link.springer.com/content/pdf/10.1007/s00261-018-1835-2.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00261-018-1835-2" target="_blank" >10.1007/s00261-018-1835-2</a>
Alternative languages
Result language
angličtina
Original language name
Influence of slice thickness on result of CT histogram analysis in indeterminate adrenal masses.
Original language description
PURPOSE: The aim was to determine the optimal slice thickness of CT images and the optimal threshold of negative voxels for CT histogram analysis to distinguish adrenal adenomas from non-adenomas with a mean attenuation more than 10 Hounsfield units (HU). METHODS: Volume CT histogram analysis of 83 lipid-poor adenomas and 80 non-adenomas was performed retrospectively. The volume of interest was extracted from each adrenal lesion, and the mean attenuation, standard deviation (SD), and percentage of voxels with a negative CT value were recorded using reconstructions with different slice thicknesses (5 mm, 2.5 mm, 1.25 mm). The percentage of negative voxels was correlated with SD as a measure of image noise and with the reference splenic tissue values. The sensitivity, specificity, and positive predictive value (PPV) for the identification of adenomas were calculated using reconstructions with different slice thicknesses and three different thresholds of negative voxels (1%, 5%, 10%). RESULTS: The percentage of negative voxels increased with a thinner slice thickness and correlated with increasing CT image noise in adenomas, non-adenomas, and spleen. Using a threshold of 10% negative voxels and a slice thickness of 5 mm, we reached a sensitivity of 53.0%, specificity of 98.8% and the highest PPV, and thus we propose this combination for clinical use. Other combinations achieved a clearly lower specificity and PPV as a result of the increasing noise in CT images. CONCLUSION: The CT slice thickness significantly affects the result and diagnostic value of histogram analysis. Thin CT slice reconstructions are inappropriate for histogram analysis.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
<a href="/en/project/NV17-31847A" target="_blank" >NV17-31847A: Optimization of diagnostic algorithm in adrenal masses</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Abdominal Radiology
ISSN
2366-004X
e-ISSN
—
Volume of the periodical
44
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
9
Pages from-to
"1461–1469"
UT code for WoS article
000462749100026
EID of the result in the Scopus database
2-s2.0-85056890518