The prototype BS-II for computer measurement of biomechanical characteristics of the human cadaverous lumbar spine

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F19%3A73597806" target="_blank" >RIV/61989592:15110/19:73597806 - isvavai.cz</a>

  • Alternative codes found

    RIV/61989592:15310/19:73597806

  • Result on the web

    <a href="https://josr-online.biomedcentral.com/articles/10.1186/s13018-019-1463-8" target="_blank" >https://josr-online.biomedcentral.com/articles/10.1186/s13018-019-1463-8</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1186/s13018-019-1463-8" target="_blank" >10.1186/s13018-019-1463-8</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The prototype BS-II for computer measurement of biomechanical characteristics of the human cadaverous lumbar spine

  • Original language description

    The new second-generation computer system BS-II (Bio-Spine-II) based on the National Instruments’ development environment has been designed and constructed for evaluating the stability of various surgical fixative methods of the cadaverous lumbar spine (L1–L5). BS-II holds the measured sample using aluminum fixtures and using four computer-controlled stepper motors; it performs a circular movement (warm up of the specimen), programmatically driven extension (back bend), right and left lateral flexion (lateral bend), left and right axial torsion (rotation), and axial compression (pressure). Four strain gauges are used to measure the stiffness of the sample. The movement of individual components (vertebrae) is contactlessly monitored by two CCD (charge couple device) cameras. The obtained data are in digital form continuously stored in the computer memory for further processing.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])

Result continuities

  • Project

    <a href="/en/project/TG01010080" target="_blank" >TG01010080: Effective Transfer of Palacký University Olomouc Results into Praxis</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Orthopaedic Surgery and Research

  • ISSN

    1749-799X

  • e-ISSN

  • Volume of the periodical

    14

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    12

  • Pages from-to

    "454-1"-"454-12"

  • UT code for WoS article

    000508134400002

  • EID of the result in the Scopus database

    2-s2.0-85077022937