All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Interleukin-6 measured using the automated electrochemiluminescence immunoassay method for the identification of intra-amniotic inflammation in preterm prelabor rupture of membranes

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F20%3A73603996" target="_blank" >RIV/61989592:15110/20:73603996 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1080/14767058.2018.1533947" target="_blank" >https://doi.org/10.1080/14767058.2018.1533947</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1080/14767058.2018.1533947" target="_blank" >10.1080/14767058.2018.1533947</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Interleukin-6 measured using the automated electrochemiluminescence immunoassay method for the identification of intra-amniotic inflammation in preterm prelabor rupture of membranes

  • Original language description

    Introduction: We aimed to compare the amniotic fluid interleukin (IL)-6 concentrations measured using the automated electrochemiluminescence immunoassay method and ELISA, and to establish an IL-6 concentration cut-off value for intra-amniotic inflammation (IAI) in preterm prelabor rupture of membranes (PPROM), which can be used in the automated electrochemiluminescence immunoassay method. Materials and methods: A total of 120 women with PPROM were included in this study. Amniotic fluid samples were obtained through transabdominal amniocentesis. IL-6 concentrations were assessed using both the automated electrochemiluminescence immunoassay method and ELISA, the current gold standard. IAI was defined as an amniotic fluid IL-6 concentration of similar to 2600 mu g/mL measured using ELISA. Results: A correlation between both assays was found (Spearman&apos;s rho = 0.97; p&lt;.0001). Based on the receiver-operating characteristic curve for the identification of IAI (area under the curve = 0.99), a cut-off value of similar to 3000 mu g/mL was selected for the automated electrochemiluminescence immunoassay method with a sensitivity of 88%, specificity of 99%, positive predictive value of 97%, negative predictive value of 96%, and likelihood ratio of 76. Conclusions: For amniotic fluid IL-6 concentrations assessed using the automated electrochemiluminescence immunoassay method, a cut-off value of 3000 mu g/mL was indicated for diagnosing IAI in women with PPROM.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30214 - Obstetrics and gynaecology

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Maternal-Fetal &amp; Neonatal Medicine

  • ISSN

    1476-7058

  • e-ISSN

  • Volume of the periodical

    33

  • Issue of the periodical within the volume

    11

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    8

  • Pages from-to

    1919-1926

  • UT code for WoS article

    000522478000001

  • EID of the result in the Scopus database

    2-s2.0-85058841426