Quality assessment of fetal middle cerebral and umbilical artery Doppler images using an objective scale within an international randomized controlled trial
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F20%3A73604860" target="_blank" >RIV/61989592:15110/20:73604860 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11150/20:10417367 RIV/00179906:_____/20:10417367
Result on the web
<a href="https://obgyn.onlinelibrary.wiley.com/doi/abs/10.1002/uog.20370" target="_blank" >https://obgyn.onlinelibrary.wiley.com/doi/abs/10.1002/uog.20370</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/uog.20370" target="_blank" >10.1002/uog.20370</a>
Alternative languages
Result language
angličtina
Original language name
Quality assessment of fetal middle cerebral and umbilical artery Doppler images using an objective scale within an international randomized controlled trial
Original language description
OBJECTIVES: To determine the quality of Doppler images of the fetal middle cerebral artery (MCA) and umbilical artery (UA) using an objective scale, and to determine the reliability of this scale, within a multicenter randomized controlled trial (Revealed versus concealed criteria for placental insufficiency in unselected obstetric population in late pregnancy (Ratio37)). METHODS: The Ratio37 trial is an ongoing randomized, open-label, multicenter controlled study of women with a low-risk pregnancy recruited at 20 weeks. Doppler measurements of the fetal MCA and UA were performed at 37 weeks. Twenty patients from each of the six participating centers were selected randomly, with two images evaluated per patient (one each for the MCA and UA). The quality of a total of 240 images was evaluated by six experts, scored on an objective scale of six items. Inter- and intrarater reliability was assessed using the Fleiss-modified kappa statistic for ordinal scales. RESULTS: On average, 89.2% of MCA images and 85.0% of UA images were rated as being of perfect (score of 6) or almost perfect (score of 5) quality. Kappa values for intrarater reliability of quality assessment were 0.90 (95% CI, 0.88-0.92) and 0.90 (95% CI, 0.88-0.93) for the MCA and UA, respectively. The corresponding inter-rater reliability values were 0.85 (95% CI, 0.81-0.89) and 0.84 (95% CI, 0.80-0.89), respectively. CONCLUSION: The quality of MCA and UA Doppler ultrasound images can be evaluated reliably using an objective scale. Over 85% of images, which were obtained by operators from a broad range of clinical practices within a multicenter study, were rated as being of perfect or almost perfect quality. Intra- and inter-rater reliability of quality assessment was very good. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30214 - Obstetrics and gynaecology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
ULTRASOUND IN OBSTETRICS & GYNECOLOGY
ISSN
0960-7692
e-ISSN
—
Volume of the periodical
56
Issue of the periodical within the volume
2
Country of publishing house
US - UNITED STATES
Number of pages
5
Pages from-to
182-186
UT code for WoS article
000543166300001
EID of the result in the Scopus database