Electrochemical Behavior and Determination of Rutin on Modified Carbon Paste Electrodes
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F12%3A33142181" target="_blank" >RIV/61989592:15310/12:33142181 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1100/2012/394756" target="_blank" >http://dx.doi.org/10.1100/2012/394756</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1100/2012/394756" target="_blank" >10.1100/2012/394756</a>
Alternative languages
Result language
angličtina
Original language name
Electrochemical Behavior and Determination of Rutin on Modified Carbon Paste Electrodes
Original language description
The performances of ionic liquid (1-hexyl-3-methylimidazolium-bis(trifluoromethylsulfonyl)imide, IL/CPE) and iron phthalocyanine (IP/CPE) modified carbon paste electrodes in electroanalytical determinations of rutin were evaluated and compared to the performance of unmodified carbon paste electrode (CPE). Cyclic voltammetry (CV), differential pulse voltammetry (DPV), differential pulse adsorptive stripping voltammetry (DPAdSV), and amperometry were used for rutin analysis. The best current responses ofrutin were obtained at pH4.0 for all tested techniques. IL/CPE electrode was found to perform best with DPAdSV technique, where a detection limit (LOD) as low as 5 nmol L-1 of rutin was found. On the other hand, IP/CPE showed itself to be an optimum choice for DPV technique, where LOD of 80 nmol L-1 was obtained. Analytical applicability of newly prepared electrodes was demonstrated on determination of rutin in the model samples and the extracts of buckwheat seeds. To find an optimum met
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/ED2.1.00%2F03.0058" target="_blank" >ED2.1.00/03.0058: Regional Centre of Advanced Technologies and Materials</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
The Scientific World Journal
ISSN
1537-744X
e-ISSN
—
Volume of the periodical
2012
Issue of the periodical within the volume
394756
Country of publishing house
US - UNITED STATES
Number of pages
9
Pages from-to
1-9
UT code for WoS article
000305125900001
EID of the result in the Scopus database
—